Determinants of Increased Transmitral Gradients Under Dynamic Isometric Handgrip Exercise After Edge‐to‐Edge Repair With the Fourth‐Generation MitraClip

Aim: Mitral regurgitation (MR) is a prevalent cardiovascular condition, and its treatment remains challenging, especially in high‐risk patients. The fourth‐generation MitraClip system (NTW and XTW) offers enhanced capabilities for repairing mitral valves (MVs) with complex anatomies. This study evaluates the haemodynamic function of MVs after edge‐to‐edge with wide MitraClip under physical stress induced by handgrip exercise stress echocardiography. Methods: This prospective study included 27 patients with severe MR. All patients underwent successful MitraClip implantation, and handgrip stress echocardiography was performed predischarge. The primary endpoint was a postprocedure mean transmitral gradient (TMG) < 5 mmHg under stress. A machine learning (ML) model using logistic regression as the learner and advanced data augmentation techniques, including random splitting of data into training and testing subsets and repeating the process 50 times, were employed to ensure robustness. Results: MitraClip implantation reduced MR severity from 3.02 ± 0.22 to 0.98 ± 0.43 ( p < 0.0001). Stress‐induced increases in heart rate, blood pressure and TMG were significant (TMG: 3.04 ± 0.90 mmHg at rest vs. 4.11 ± 1.53 mmHg under stress, p < 0.0001). Thirty‐seven percent of patients exhibited TMG ≥ 5 mmHg during stress. Predictors of elevated TMG included secondary MR, BMI, and multiple clip implantation (AUC = 0.90; 95% CI: 0.79–0.96). Despite increased TMG, no patients experienced significant symptoms or pathological MR. Conclusion: Wide MitraClips effectively reduce MR with satisfactory haemodynamic performance. Handgrip stress echocardiography is a feasible and valuable tool for assessing postprocedure valve function. Larger cohorts are necessary to confirm the impact of secondary MR and use of multiple clips on increased TMG under stress.

Authors

Institutions

Publication Details

Journal
Journal of Interventional Cardiology
Published
2025-01-01
DOI
https://doi.org/10.1155/joic/9920829
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determinants of Increased Transmitral Gradients Under Dynamic Isometric Handgrip Exercise After Edge‐to‐Edge Repair With the Fourth‐Generation MitraClip

Hüseyin İnce, Giuseppe D ́Ancona, Raid Al Ammareen, Christoph Steinbach et al.
Journal of Interventional Cardiology
Cardiac Valve Diseases and Treatments
article

Determinants of Increased Transmitral Gradients Under Dynamic Isometric Handgrip Exercise After Edge‐to‐Edge Repair With the Fourth‐Generation MitraClip

Hüseyin İnce, Giuseppe D ́Ancona, Raid Al Ammareen, Christoph Steinbach, Antonia Anna Ourani, Evangelos Chaidos
article en

Abstract

Aim: Mitral regurgitation (MR) is a prevalent cardiovascular condition, and its treatment remains challenging, especially in high‐risk patients. The fourth‐generation MitraClip system (NTW and XTW) offers enhanced capabilities for repairing mitral valves (MVs) with complex anatomies. This study evaluates the haemodynamic function of MVs after edge‐to‐edge with wide MitraClip under physical stress induced by handgrip exercise stress echocardiography. Methods: This prospective study included 27 patients with severe MR. All patients underwent successful MitraClip implantation, and handgrip stress echocardiography was performed predischarge. The primary endpoint was a postprocedure mean transmitral gradient (TMG) < 5 mmHg under stress. A machine learning (ML) model using logistic regression as the learner and advanced data augmentation techniques, including random splitting of data into training and testing subsets and repeating the process 50 times, were employed to ensure robustness. Results: MitraClip implantation reduced MR severity from 3.02 ± 0.22 to 0.98 ± 0.43 ( p < 0.0001). Stress‐induced increases in heart rate, blood pressure and TMG were significant (TMG: 3.04 ± 0.90 mmHg at rest vs. 4.11 ± 1.53 mmHg under stress, p < 0.0001). Thirty‐seven percent of patients exhibited TMG ≥ 5 mmHg during stress. Predictors of elevated TMG included secondary MR, BMI, and multiple clip implantation (AUC = 0.90; 95% CI: 0.79–0.96). Despite increased TMG, no patients experienced significant symptoms or pathological MR. Conclusion: Wide MitraClips effectively reduce MR with satisfactory haemodynamic performance. Handgrip stress echocardiography is a feasible and valuable tool for assessing postprocedure valve function. Larger cohorts are necessary to confirm the impact of secondary MR and use of multiple clips on increased TMG under stress.

Journal of Interventional CardiologyVol. 2025(1)
Chamber of Deputies (IT), Vivantes Klinikum (DE), University of Rostock (DE)
Good health and well-being
Openalex Percentile: Top 67%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.