A novel portable device and validation procedure for transcutaneous electrical nerve stimulation

The adoption of upper limb myoelectric prosthesis is limited by the lack of closed control loop systems. Although the efferent control has already been integrated into these devices, the sensory feedback restoration in the afferent channel still remains an open challenge. Transcutaneous electrical nerve stimulation (TENS) is a promising method for generating somatotopic sensory feedback, allowing the closure of the control loop system. The application of this technique is limited by cumbersome and grid-powered electrical stimulators, making them unsuitable for everyday life, whereas most portable stimulators available on the market are designed for other purposes (e.g., muscular stimulation or pain therapy) and present limited stimulation wave customization. The stimulation devices employed in the literature often produce not fully suitable stimulation parameters and are frequently validated through procedures that do not fully clarify their practical application for sensory feedback restoration. The research aims to present a novel wearable TENS stimulation device (46 g, 62 × 49 × 20 mm) suitable for sensory feedback application. The validation was achieved through a benchtop test and a preliminary analysis on 10 healthy participants comparing the qualities, intensities, and stimulated areas of the sensations elicited by the proposed device and a reference stimulator. The proposed device is capable of delivering charge-balanced stimulation waves over skin-like resistive load and eliciting tingling and vibration sensations with similar intensities compared to the adopted reference.

Authors

Institutions

Publication Details

Journal
Wearable Technologies
Published
2025-01-01
DOI
https://doi.org/10.1017/wtc.2025.10004
Citations
2
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel portable device and validation procedure for transcutaneous electrical nerve stimulation

Andreas Demosthenous, Loredana Zollo, Dai Jiang, R. Paolini et al.
2 citations
Wearable Technologies
Muscle activation and electromyography studies
1.35
article

A novel portable device and validation procedure for transcutaneous electrical nerve stimulation

Andreas Demosthenous, Loredana Zollo, Dai Jiang, R. Paolini, Andrea Demofonti, Alessia Scarpelli, Francesca Cordella, Fangqi Liu
article en
2 citations

Abstract

The adoption of upper limb myoelectric prosthesis is limited by the lack of closed control loop systems. Although the efferent control has already been integrated into these devices, the sensory feedback restoration in the afferent channel still remains an open challenge. Transcutaneous electrical nerve stimulation (TENS) is a promising method for generating somatotopic sensory feedback, allowing the closure of the control loop system. The application of this technique is limited by cumbersome and grid-powered electrical stimulators, making them unsuitable for everyday life, whereas most portable stimulators available on the market are designed for other purposes (e.g., muscular stimulation or pain therapy) and present limited stimulation wave customization. The stimulation devices employed in the literature often produce not fully suitable stimulation parameters and are frequently validated through procedures that do not fully clarify their practical application for sensory feedback restoration. The research aims to present a novel wearable TENS stimulation device (46 g, 62 × 49 × 20 mm) suitable for sensory feedback application. The validation was achieved through a benchtop test and a preliminary analysis on 10 healthy participants comparing the qualities, intensities, and stimulated areas of the sensations elicited by the proposed device and a reference stimulator. The proposed device is capable of delivering charge-balanced stimulation waves over skin-like resistive load and eliciting tingling and vibration sensations with similar intensities compared to the adopted reference.

Wearable TechnologiesVol. 6
Università Campus Bio-Medico (IT), University College London (GB)
Life in Land
Openalex Percentile: Top 18%
Muscle activation and electromyography studies
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.