A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant

Biogas as one of the renewable energy sources contains hydrogen sulfide (H₂S) which causes equipment corrosion and gives negative impacts on the environment. To study some factors that affect the H2S removal efficiency, evaluation was done on the performance of existing H2S scrubber. For the case study, it was found that the existing scrubber performance did not reach the target (< 200 ppm-v H2S) with 1,450 Nm3 biogas/h and 2,550 ppm-v H2S inlet (-10 mbarg and 35oC). Scenarios were made by varying the design parameters of the H2S outlet scrubber (0 - 1,140 ppm-v), H2S inlet scrubber (2,550 and 3,000 ppm-v), and biogas flow (1,450 and 1,700 Nm3 biogas/h). Based on the analysis results, it was found that the initial design had already considered an overdesign factor of at least 52 times. Through solubility and residence time analysis, favorable scrubber operation is to run at low liquid spray flow (~ 70 m3/h). In addition, low flow liquid spray could help activate the bacteria on the bio-packing media surfaces so that they are not eroded by the high erosive spray velocity. This study’s results are expected to be a reference for the biogas industry in evaluating the performance of H2S scrubbers.

Authors

Institutions

Publication Details

Journal
Rekayasa
Published
2024-12-31
DOI
https://doi.org/10.15294/rekayasa.v22i2.30454
Primary Topic
Industrial Gas Emission Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant

Hanif Ardhiansyah, Muhammad Ikram, Ramavi Akbar
Rekayasa
Industrial Gas Emission Control
article

A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant

Hanif Ardhiansyah, Muhammad Ikram, Ramavi Akbar
article en

Abstract

Biogas as one of the renewable energy sources contains hydrogen sulfide (H₂S) which causes equipment corrosion and gives negative impacts on the environment. To study some factors that affect the H2S removal efficiency, evaluation was done on the performance of existing H2S scrubber. For the case study, it was found that the existing scrubber performance did not reach the target (< 200 ppm-v H2S) with 1,450 Nm3 biogas/h and 2,550 ppm-v H2S inlet (-10 mbarg and 35oC). Scenarios were made by varying the design parameters of the H2S outlet scrubber (0 - 1,140 ppm-v), H2S inlet scrubber (2,550 and 3,000 ppm-v), and biogas flow (1,450 and 1,700 Nm3 biogas/h). Based on the analysis results, it was found that the initial design had already considered an overdesign factor of at least 52 times. Through solubility and residence time analysis, favorable scrubber operation is to run at low liquid spray flow (~ 70 m3/h). In addition, low flow liquid spray could help activate the bacteria on the bio-packing media surfaces so that they are not eroded by the high erosive spray velocity. This study’s results are expected to be a reference for the biogas industry in evaluating the performance of H2S scrubbers.

RekayasaVol. 22(2)
State University of Semarang (ID), State Research Institute of Mechanical Engineering (RU)
Affordable and clean energy
Openalex Percentile: Top 70%
Industrial Gas Emission Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Simple Method in Evaluating the Performance of H2S Scrubber at Existing Biogas Plant — Hanif Ardhiansyah, Muhammad Ikram, et al. · Rekayasa (2024) | TGRS Research Map | TGRS