Water Vapor Transmission Properties of Autoclaved Aerated Concrete of Four Density Classes—Experimental Determination in Stationary Processes

Moisture in porous building materials significantly affects all their technical parameters. For this reason, it is important to accurately determine coefficients that describe moisture transport inside these materials. The main parameters concerning the hygroscopic range are as follows: water vapor permeability δ, water vapor resistance factor μ, and water vapor diffusion coefficient D. Autoclaved aerated concrete (AAC), one of the most popular materials used for the construction of external walls, was tested. The study focused on the four density classes: 400, 500, 600, and 700. Using a modified cup method, measurements of the corresponding coefficients δ, μ, D were carried out in six ranges of relative air humidity: 11–30, 30–54, 54–60, 60–75, 75–85, 85–98%. The results prove that not only the level of humidity tested, but also the structure within the same material group has a significant impact on all parameters, strongly differentiating their values. In this regard, precise numerical simulations concerning moisture transport processes in autoclaved aerated concrete must take into account both its density class and the moisture range in which these processes occur.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-08-10
DOI
https://doi.org/10.3390/app15168818
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Water Vapor Transmission Properties of Autoclaved Aerated Concrete of Four Density Classes—Experimental Determination in Stationary Processes

Magdalena Bochenek, H. Garbalińska
Applied Sciences
Hygrothermal properties of building materials
article

Water Vapor Transmission Properties of Autoclaved Aerated Concrete of Four Density Classes—Experimental Determination in Stationary Processes

Magdalena Bochenek, H. Garbalińska
article en

Abstract

Moisture in porous building materials significantly affects all their technical parameters. For this reason, it is important to accurately determine coefficients that describe moisture transport inside these materials. The main parameters concerning the hygroscopic range are as follows: water vapor permeability δ, water vapor resistance factor μ, and water vapor diffusion coefficient D. Autoclaved aerated concrete (AAC), one of the most popular materials used for the construction of external walls, was tested. The study focused on the four density classes: 400, 500, 600, and 700. Using a modified cup method, measurements of the corresponding coefficients δ, μ, D were carried out in six ranges of relative air humidity: 11–30, 30–54, 54–60, 60–75, 75–85, 85–98%. The results prove that not only the level of humidity tested, but also the structure within the same material group has a significant impact on all parameters, strongly differentiating their values. In this regard, precise numerical simulations concerning moisture transport processes in autoclaved aerated concrete must take into account both its density class and the moisture range in which these processes occur.

Applied SciencesVol. 15(16)
West Pomeranian University of Technology in Szczecin (PL)
Clean water and sanitation
Openalex Percentile: Top 78%
Hygrothermal properties of building materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.