Validity and Reliability of an Inertial Measurement Sensor for Measuring Elastic Force and Time Under Tension in Shoulder Abduction and Knee Extension

(1) Background: Several tools have been proposed to measure elastic band tension and time under tension (TUT) during elastic band exercise performance. However, current methods are often indirect, non-objective, or expensive. The Elastic Force Evaluation Bracelet (EFEB) is a simple, wearable system designed to estimate both variables. Therefore, the aim of this study was to evaluate the concurrent validity and test–retest reliability of the EFEB as a portable measurement device for application in a therapeutic exercise context. (2) Methods: Thirty-five healthy volunteers were recruited. Exercises with elastic bands were performed on the dominant upper and lower limbs in two sessions with a one-week interval between them, and peak elastic force values were obtained. Validity was assessed in the first session by comparing the force values obtained simultaneously using a force gauge, and the TUT compared to a linear encoder. Test–retest reliability was examined by comparing the measurements obtained between the two sessions. (3) Results: EFEB showed excellent correlation with the force gauge for elastic force (r = 0.883 for shoulder abduction and r = 0.981 for knee extension) and with the linear encoder for TUTs (r = 0.873 and r = 0.883, respectively). EFEB showed good levels of reliability for all four of the following parameters measured: elastic force for shoulder abduction and knee extension (ICC = 0.880 and 0.855, respectively), and TUT in both movements (ICC = 0.768 and 0.765, respectively). (4) Conclusions: In conclusion, EFEB is a valid and reliable device for the measurement of TUT during shoulder abduction and knee extension exercises performed with elastic bands.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-08-11
DOI
https://doi.org/10.3390/app15168846
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity and Reliability of an Inertial Measurement Sensor for Measuring Elastic Force and Time Under Tension in Shoulder Abduction and Knee Extension

Borja Tronchoni-Crespo, F. Martín, Rodrigo Martín‐San Agustín, Noemí Moreno‐Segura et al.
Applied Sciences
Sports Performance and Training
article

Validity and Reliability of an Inertial Measurement Sensor for Measuring Elastic Force and Time Under Tension in Shoulder Abduction and Knee Extension

Borja Tronchoni-Crespo, F. Martín, Rodrigo Martín‐San Agustín, Noemí Moreno‐Segura, Jesus Aguiló-Furio
article en

Abstract

(1) Background: Several tools have been proposed to measure elastic band tension and time under tension (TUT) during elastic band exercise performance. However, current methods are often indirect, non-objective, or expensive. The Elastic Force Evaluation Bracelet (EFEB) is a simple, wearable system designed to estimate both variables. Therefore, the aim of this study was to evaluate the concurrent validity and test–retest reliability of the EFEB as a portable measurement device for application in a therapeutic exercise context. (2) Methods: Thirty-five healthy volunteers were recruited. Exercises with elastic bands were performed on the dominant upper and lower limbs in two sessions with a one-week interval between them, and peak elastic force values were obtained. Validity was assessed in the first session by comparing the force values obtained simultaneously using a force gauge, and the TUT compared to a linear encoder. Test–retest reliability was examined by comparing the measurements obtained between the two sessions. (3) Results: EFEB showed excellent correlation with the force gauge for elastic force (r = 0.883 for shoulder abduction and r = 0.981 for knee extension) and with the linear encoder for TUTs (r = 0.873 and r = 0.883, respectively). EFEB showed good levels of reliability for all four of the following parameters measured: elastic force for shoulder abduction and knee extension (ICC = 0.880 and 0.855, respectively), and TUT in both movements (ICC = 0.768 and 0.765, respectively). (4) Conclusions: In conclusion, EFEB is a valid and reliable device for the measurement of TUT during shoulder abduction and knee extension exercises performed with elastic bands.

Applied SciencesVol. 15(16)
Universitat de València (ES), IMDEA Energy Institute (ES)
Openalex Percentile: Top 74%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.