Lessons Learned in Pressure and Flow Measurement of SCO2 Systems From the STEP Demo Facility

Abstract Measurement of supercritical CO2 pressure and flow can pose challenges not seen with other fluids and, especially, ideal gases. This paper describes several of the flow measurement challenges experienced at the STEP facility as well as the solutions implemented. Many flow meters within the facility rely on differential pressure measurements across an orifice plate flow meter. These differential pressure transducers utilize relatively long static sensing lines to the orifice flanges. Because of the specific operating pressure and temperature of some flow meters, CO2 within the sensing lines is believed to condense to a liquid or a dense phase if no mitigation steps are taken. If the high- and low-pressure lines are not routed identically, this densification can lead to significant hydrostatic head differences and negatively affect the differential pressure measurement, and, therefore, the flow measurements. One effective mitigation measure was adding heat trace and insulation to maintain a sensing line temperature well above the critical point of CO2. The presence of fluids other than CO2 can also lead to these hydrostatic head differences due to density differences at pressure, especially if the tube routing creates low or high point “traps”. Care must be taken to purge other fluids from each sensing line prior to operation. This paper presents operating data before and after several mitigation measures were implemented, demonstrating the effectiveness of the measures in improving flow measurements. Flow tests were performed with multiple inline flow meters to confirm measurement improvement through relative mass flow rate agreement of the upstream and downstream meters. CO2 was pumped from a liquid storage tank and vaporized before passing through one of two legs of the test setup. Various pressures, temperatures, and flow rates were investigated to help determine when the flow discrepancies were most prevalent, and to verify that the mitigation measures implemented were effective across a range of conditions.

Authors

Institutions

Publication Details

Published
2025-06-16
DOI
https://doi.org/10.1115/gt2025-152229
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lessons Learned in Pressure and Flow Measurement of SCO2 Systems From the STEP Demo Facility

Craig Nolen, George Khawly
Advanced Sensor Technologies Research
article

Lessons Learned in Pressure and Flow Measurement of SCO2 Systems From the STEP Demo Facility

Craig Nolen, George Khawly
article en

Abstract

Abstract Measurement of supercritical CO2 pressure and flow can pose challenges not seen with other fluids and, especially, ideal gases. This paper describes several of the flow measurement challenges experienced at the STEP facility as well as the solutions implemented. Many flow meters within the facility rely on differential pressure measurements across an orifice plate flow meter. These differential pressure transducers utilize relatively long static sensing lines to the orifice flanges. Because of the specific operating pressure and temperature of some flow meters, CO2 within the sensing lines is believed to condense to a liquid or a dense phase if no mitigation steps are taken. If the high- and low-pressure lines are not routed identically, this densification can lead to significant hydrostatic head differences and negatively affect the differential pressure measurement, and, therefore, the flow measurements. One effective mitigation measure was adding heat trace and insulation to maintain a sensing line temperature well above the critical point of CO2. The presence of fluids other than CO2 can also lead to these hydrostatic head differences due to density differences at pressure, especially if the tube routing creates low or high point “traps”. Care must be taken to purge other fluids from each sensing line prior to operation. This paper presents operating data before and after several mitigation measures were implemented, demonstrating the effectiveness of the measures in improving flow measurements. Flow tests were performed with multiple inline flow meters to confirm measurement improvement through relative mass flow rate agreement of the upstream and downstream meters. CO2 was pumped from a liquid storage tank and vaporized before passing through one of two legs of the test setup. Various pressures, temperatures, and flow rates were investigated to help determine when the flow discrepancies were most prevalent, and to verify that the mitigation measures implemented were effective across a range of conditions.

Southwest Research Institute (US)
Openalex Percentile: Top 81%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Lessons Learned in Pressure and Flow Measurement of SCO2 Systems From the STEP Demo Facility — Craig Nolen, George Khawly · (2025) | TGRS Research Map | TGRS