Experimental Investigation of Mach Number Effect on Overall Cooling Effectiveness for a Transonic Vane

Abstract To keep metal temperature at allowable levels in modern gas turbine engines, both internal and external (film) cooling is necessary. The simultaneous influence of both of these effects is represented by an overall cooling effectiveness, which can be measured in appropriately scaled lab experiments. In most previous studies, the overall cooling effectiveness for a first stage vane was obtained in low-speed experiments, where it is appropriate to assume that the hot fluid reference temperature (typically the mainstream gas temperature) is constant. However, to provide better application to real gas turbine operating conditions, it is necessary to quantify the effects of Mach number on the overall cooling effectiveness. Specifically, for high-speed flows, a more appropriate hot fluid reference temperature is the recovery temperature. This arises due to the viscous dissipation within the boundary layer, and which varies locally around the airfoil depending on the local Mach number and boundary layer state. To understand the influence of Mach number on overall effectiveness, a metallic film cooled vane with cylindrical showerhead, pressure side, and suction side film cooling rows was experimentally tested in a high-speed linear cascade rig at exit Mach numbers ranging from 0.7 to 1.1 and varying blowing ratios. The vane was designed with two cavities that were independently fed with coolant. Measurements of the vane outer surface temperature were obtained with infrared thermography. In addition to studies with both cavities flowing, a study of superposition of overall cooling was performed by switching off individual cavities. This study showed that cooling effectiveness did not significantly change with Mach number. This study also showed that the principle of superposition for overall effectiveness can be applied to film cooled vanes at transonic conditions. Additionally, the appropriate reference temperature for overall cooling effectiveness was explored. While utilizing the recovery temperature as the reference temperature resulted in collapse of overall effectiveness at subsonic exit Mach number, the inlet total temperature is a better reference temperature in some cases particularly where shocks are present.

Authors

Institutions

Publication Details

Published
2025-06-16
DOI
https://doi.org/10.1115/gt2025-153929
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of Mach Number Effect on Overall Cooling Effectiveness for a Transonic Vane

Stephen Lynch, Matthew Krull
Turbomachinery Performance and Optimization
article

Experimental Investigation of Mach Number Effect on Overall Cooling Effectiveness for a Transonic Vane

Stephen Lynch, Matthew Krull
article en

Abstract

Abstract To keep metal temperature at allowable levels in modern gas turbine engines, both internal and external (film) cooling is necessary. The simultaneous influence of both of these effects is represented by an overall cooling effectiveness, which can be measured in appropriately scaled lab experiments. In most previous studies, the overall cooling effectiveness for a first stage vane was obtained in low-speed experiments, where it is appropriate to assume that the hot fluid reference temperature (typically the mainstream gas temperature) is constant. However, to provide better application to real gas turbine operating conditions, it is necessary to quantify the effects of Mach number on the overall cooling effectiveness. Specifically, for high-speed flows, a more appropriate hot fluid reference temperature is the recovery temperature. This arises due to the viscous dissipation within the boundary layer, and which varies locally around the airfoil depending on the local Mach number and boundary layer state. To understand the influence of Mach number on overall effectiveness, a metallic film cooled vane with cylindrical showerhead, pressure side, and suction side film cooling rows was experimentally tested in a high-speed linear cascade rig at exit Mach numbers ranging from 0.7 to 1.1 and varying blowing ratios. The vane was designed with two cavities that were independently fed with coolant. Measurements of the vane outer surface temperature were obtained with infrared thermography. In addition to studies with both cavities flowing, a study of superposition of overall cooling was performed by switching off individual cavities. This study showed that cooling effectiveness did not significantly change with Mach number. This study also showed that the principle of superposition for overall effectiveness can be applied to film cooled vanes at transonic conditions. Additionally, the appropriate reference temperature for overall cooling effectiveness was explored. While utilizing the recovery temperature as the reference temperature resulted in collapse of overall effectiveness at subsonic exit Mach number, the inlet total temperature is a better reference temperature in some cases particularly where shocks are present.

Pennsylvania State University (US)
Affordable and clean energy
Openalex Percentile: Top 71%
Turbomachinery Performance and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Investigation of Mach Number Effect on Overall Cooling Effectiveness for a Transonic Vane — Stephen Lynch, Matthew Krull · (2025) | TGRS Research Map | TGRS