Clinical and cone beam radiographic evaluation of different designs of hybrid implant abutment-crowns

Abstract Background Dental implant therapy is reliable for replacing missing teeth, but single-implant restorations face higher biomechanical challenges. This study explores how abutment design influences peri-implant tissue health and marginal bone levels, testing the null hypothesis that restoration design does not affect peri-implant hard and soft tissue responses over time. Patients and methods A total of 30 patients, aged 25–55 years and medically free, were selected based on strict inclusion and exclusion criteria. Each patient received an implant with zirconia restorations milled on titanium inserts. Participants were randomly assigned to two treatment groups: group 1: Hybrid abutment-crown (one-piece design) and group 2: Hybrid abutment with a separate crown (two-piece design). Probing depth (PD) was clinically assessed at baseline (48 h postprosthesis placement), 6, and 12 months. Radiographic assessments were conducted using cone beam computed tomography to evaluate vertical facial bone loss. Results Regarding marginal bone loss (MBL), significant differences were observed between the two groups ( P < 0.001). Regarding PD, the results showed a significant difference in PD across the follow-up periods ( P < 0.001) but no significant difference between the two designs ( P = 0.166). However, a significant interaction was found between design and follow-up periods ( P < 0.001). Conclusion The study demonstrated that restoration design significantly impacts MBL and PD over time. MBL was significantly higher in the one-piece design compared to the two-piece design, suggesting that the hybrid-abutment design of the two-piece system provides better force dissipation and stress distribution.

Authors

Institutions

Publication Details

Journal
Tanta Dental Journal
Published
2025-04-01
DOI
https://doi.org/10.4103/tdj.tdj_129_24
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical and cone beam radiographic evaluation of different designs of hybrid implant abutment-crowns

Mohiuddin Ahmed, Amany Korsel, Waleed M. Elshehawy
Tanta Dental Journal
Dental Implant Techniques and Outcomes
article

Clinical and cone beam radiographic evaluation of different designs of hybrid implant abutment-crowns

Mohiuddin Ahmed, Amany Korsel, Waleed M. Elshehawy
article en

Abstract

Abstract Background Dental implant therapy is reliable for replacing missing teeth, but single-implant restorations face higher biomechanical challenges. This study explores how abutment design influences peri-implant tissue health and marginal bone levels, testing the null hypothesis that restoration design does not affect peri-implant hard and soft tissue responses over time. Patients and methods A total of 30 patients, aged 25–55 years and medically free, were selected based on strict inclusion and exclusion criteria. Each patient received an implant with zirconia restorations milled on titanium inserts. Participants were randomly assigned to two treatment groups: group 1: Hybrid abutment-crown (one-piece design) and group 2: Hybrid abutment with a separate crown (two-piece design). Probing depth (PD) was clinically assessed at baseline (48 h postprosthesis placement), 6, and 12 months. Radiographic assessments were conducted using cone beam computed tomography to evaluate vertical facial bone loss. Results Regarding marginal bone loss (MBL), significant differences were observed between the two groups ( P < 0.001). Regarding PD, the results showed a significant difference in PD across the follow-up periods ( P < 0.001) but no significant difference between the two designs ( P = 0.166). However, a significant interaction was found between design and follow-up periods ( P < 0.001). Conclusion The study demonstrated that restoration design significantly impacts MBL and PD over time. MBL was significantly higher in the one-piece design compared to the two-piece design, suggesting that the hybrid-abutment design of the two-piece system provides better force dissipation and stress distribution.

Tanta Dental JournalVol. 22(2)
Tanta University (EG)
Openalex Percentile: Top 71%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Clinical and cone beam radiographic evaluation of different designs of hybrid implant abutment-crowns — Mohiuddin Ahmed, Amany Korsel, et al. · Tanta Dental Journal (2025) | TGRS Research Map | TGRS