Performance and Evaluation of a Thermally Optimized Gas Turbine Nozzle

Abstract This study evaluated the overall cooling effectiveness of a newly designed turbine airfoil using optimized internal and external cooling features. A symmetric airfoil, which incorporated advanced cooling schemes enabled by additive manufacturing, was designed for testing in a high temperature hydrogen fueled combustor facility. The design of this airfoil is described in a companion study. This paper describes the experimental and computational evaluation of the new design to ensure that the test model would have sufficient cooling to operate in the high temperature combustor. Tests were performed in a low temperature wind tunnel facility, matching the Mach number and Reynolds number of the combustor test facility. Further insight into the cooling performance and analysis of the experimental results was obtained using computational predictions. Experimental testing included a low conductivity model that was used to estimate adiabatic effectiveness for film cooling configurations. A high conductivity model, which matched the Biot number expected for operation in the combustor facility, was tested to obtain overall cooling effectiveness. Experimental results showed adiabatic effectiveness was generally above η¯ = 0.3, though there was a small region that fell below η¯. Overall cooling effectiveness was quite uniform ranging from ϕ¯ = 0.54 to 0.63 over the complete airfoil. Reynolds-Averaged Navier-Stokes (RANS) computations were consistent with the experimental trends. The RANS predictions were particularly useful in showing how conduction effects in the low temperature model were affecting the measurements of adiabatic effectiveness. The experiments and computational predictions verified that the design intent to have a relatively uniform overall effectiveness of greater than ϕ¯ = 0.55 was achieved. The study also identified deficiencies in the cooling design that could potentially be addressed leading to improved overall cooling effectiveness.

Authors

Institutions

Publication Details

Published
2025-06-16
DOI
https://doi.org/10.1115/gt2025-153337
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance and Evaluation of a Thermally Optimized Gas Turbine Nozzle

David G. Bogard, Elise M. Flachs
Turbomachinery Performance and Optimization
article

Performance and Evaluation of a Thermally Optimized Gas Turbine Nozzle

David G. Bogard, Elise M. Flachs
article en

Abstract

Abstract This study evaluated the overall cooling effectiveness of a newly designed turbine airfoil using optimized internal and external cooling features. A symmetric airfoil, which incorporated advanced cooling schemes enabled by additive manufacturing, was designed for testing in a high temperature hydrogen fueled combustor facility. The design of this airfoil is described in a companion study. This paper describes the experimental and computational evaluation of the new design to ensure that the test model would have sufficient cooling to operate in the high temperature combustor. Tests were performed in a low temperature wind tunnel facility, matching the Mach number and Reynolds number of the combustor test facility. Further insight into the cooling performance and analysis of the experimental results was obtained using computational predictions. Experimental testing included a low conductivity model that was used to estimate adiabatic effectiveness for film cooling configurations. A high conductivity model, which matched the Biot number expected for operation in the combustor facility, was tested to obtain overall cooling effectiveness. Experimental results showed adiabatic effectiveness was generally above η¯ = 0.3, though there was a small region that fell below η¯. Overall cooling effectiveness was quite uniform ranging from ϕ¯ = 0.54 to 0.63 over the complete airfoil. Reynolds-Averaged Navier-Stokes (RANS) computations were consistent with the experimental trends. The RANS predictions were particularly useful in showing how conduction effects in the low temperature model were affecting the measurements of adiabatic effectiveness. The experiments and computational predictions verified that the design intent to have a relatively uniform overall effectiveness of greater than ϕ¯ = 0.55 was achieved. The study also identified deficiencies in the cooling design that could potentially be addressed leading to improved overall cooling effectiveness.

The University of Texas at Austin (US)
Affordable and clean energy
Openalex Percentile: Top 71%
Turbomachinery Performance and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.