Effect of Seawater Flow on Low-Pressure Steam Turbine Isentropic Efficiency and Exhaust Moisture Content

Abstract Adequate seawater (SW) flow or cooling water flow through the condenser in a thermal power plant is a critical factor in maintaining the isentropic efficiency of the LP steam turbine, condenser pressure and moisture content at the turbine exhaust. At one of ACWA Power’s thermal sites, deviations from the design seawater flow rates were identified during operation, as compared to the original equipment manufacturers HMBs. The site was operating three pumps on two blocks instead of the required four pumps, two on each block due to the constraints in the SW pit level. An investigation was conducted using thermodynamic modeling software to assess the impact of reduced SW flow on the LP turbine’s performance and condenser pressure. The analysis indicated that the LP turbine’s isentropic efficiency and condenser pressure and exhaust moisture content were deviating from the design reference due to the inadequate SW flow. To validate these findings, actual plant data was analyzed. It was observed that when sufficient SW flow was restored, moisture content, condenser pressure and isentropic efficiency returned to the expected levels with the improvement of around 40–45 KJ/KWh in steam cycle heat rate.

Authors

Institutions

Publication Details

Published
2025-06-16
DOI
https://doi.org/10.1115/gt2025-153694
Primary Topic
Advanced Power Generation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Seawater Flow on Low-Pressure Steam Turbine Isentropic Efficiency and Exhaust Moisture Content

M. B. I. Janjua, Jalal Zia, Yahya Zafar, Muhammad Adnan Saroosh
Advanced Power Generation Technologies
article

Effect of Seawater Flow on Low-Pressure Steam Turbine Isentropic Efficiency and Exhaust Moisture Content

M. B. I. Janjua, Jalal Zia, Yahya Zafar, Muhammad Adnan Saroosh
article en

Abstract

Abstract Adequate seawater (SW) flow or cooling water flow through the condenser in a thermal power plant is a critical factor in maintaining the isentropic efficiency of the LP steam turbine, condenser pressure and moisture content at the turbine exhaust. At one of ACWA Power’s thermal sites, deviations from the design seawater flow rates were identified during operation, as compared to the original equipment manufacturers HMBs. The site was operating three pumps on two blocks instead of the required four pumps, two on each block due to the constraints in the SW pit level. An investigation was conducted using thermodynamic modeling software to assess the impact of reduced SW flow on the LP turbine’s performance and condenser pressure. The analysis indicated that the LP turbine’s isentropic efficiency and condenser pressure and exhaust moisture content were deviating from the design reference due to the inadequate SW flow. To validate these findings, actual plant data was analyzed. It was observed that when sufficient SW flow was restored, moisture content, condenser pressure and isentropic efficiency returned to the expected levels with the improvement of around 40–45 KJ/KWh in steam cycle heat rate.

Institute of Power Engineering (PL)
Life below water
Openalex Percentile: Top 81%
Advanced Power Generation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Seawater Flow on Low-Pressure Steam Turbine Isentropic Efficiency and Exhaust Moisture Content — M. B. I. Janjua, Jalal Zia, et al. · (2025) | TGRS Research Map | TGRS