Highly efficient and toxicologically safe ZnO(NP)@GO nanocomposite in the simultaneous detection of Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺ in aqueous medium

• Highly efficient and safe ZnO(NP)@GO thin film electrode in trace and simultaneous detection of Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺. • The thin film electrode has a relatively higher shelf life and is stable for repeated uses. • The electrode is promising in the simultaneous and trace-level detection of these heavy metal ions from hospital wastewater. Miniaturised devices for trace, simultaneous and off-site detection are the need of the hour for protecting public health and the environment at large. Using sustainable and greener approach, the current study explores using Acmella oleracea extract to derive zinc oxide nanoparticles. Further, ZnO incorporates graphene oxide to obtain the nanocomposite material (ZnO(NP)@GO). The thin film electrode using the ZnO(NP)@GO efficiently detects potential heavy metal ions viz. , Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺ individually and simultaneously at trace level concentrations. The thin film electrode using the ZnO(NP)@GO showed significantly enhanced electroactive surface area and reduced electron transfer resistance compared to the unmodified glassy carbon electrode. The calibration curve for detecting Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺ shows the limits of detection of 0.026, 0.03, 0.010 and 0.020 µgL⁻¹, respectively, in their simultaneous detection. The ZnO(NP)@GO thin film electrode possesses good shelf life and stability for repeated detections of these heavy metal toxic ions. Furthermore, the thin film electrode detects simultaneously these ions at trace levels in the hospital effluent waters with real implications. Moreover, the acute toxicity of ZnO(NP)@GO towards D. magna shows an EC 50 value of 115.7 mgL⁻¹ after 48 hrs, proving the safety and environmental sustainability of the modified electrode.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2025-08-11
DOI
https://doi.org/10.1016/j.snr.2025.100373
Citations
2
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
1.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly efficient and toxicologically safe ZnO(NP)@GO nanocomposite in the simultaneous detection of Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺ in aqueous medium

Jinho Jung, Diwakar Tiwari, Melody Lalhruaitluangi, Lalruatkima Ralte
2 citations
Sensors and Actuators Reports
Electrochemical Analysis and Applications
1.03
article

Highly efficient and toxicologically safe ZnO(NP)@GO nanocomposite in the simultaneous detection of Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺ in aqueous medium

Jinho Jung, Diwakar Tiwari, Melody Lalhruaitluangi, Lalruatkima Ralte
article en
2 citations

Abstract

• Highly efficient and safe ZnO(NP)@GO thin film electrode in trace and simultaneous detection of Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺. • The thin film electrode has a relatively higher shelf life and is stable for repeated uses. • The electrode is promising in the simultaneous and trace-level detection of these heavy metal ions from hospital wastewater. Miniaturised devices for trace, simultaneous and off-site detection are the need of the hour for protecting public health and the environment at large. Using sustainable and greener approach, the current study explores using Acmella oleracea extract to derive zinc oxide nanoparticles. Further, ZnO incorporates graphene oxide to obtain the nanocomposite material (ZnO(NP)@GO). The thin film electrode using the ZnO(NP)@GO efficiently detects potential heavy metal ions viz. , Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺ individually and simultaneously at trace level concentrations. The thin film electrode using the ZnO(NP)@GO showed significantly enhanced electroactive surface area and reduced electron transfer resistance compared to the unmodified glassy carbon electrode. The calibration curve for detecting Cd²⁺, Hg²⁺, Pb²⁺, and Zn²⁺ shows the limits of detection of 0.026, 0.03, 0.010 and 0.020 µgL⁻¹, respectively, in their simultaneous detection. The ZnO(NP)@GO thin film electrode possesses good shelf life and stability for repeated detections of these heavy metal toxic ions. Furthermore, the thin film electrode detects simultaneously these ions at trace levels in the hospital effluent waters with real implications. Moreover, the acute toxicity of ZnO(NP)@GO towards D. magna shows an EC 50 value of 115.7 mgL⁻¹ after 48 hrs, proving the safety and environmental sustainability of the modified electrode.

Sensors and Actuators ReportsVol. 10
Mizoram University (IN), Korea University (KR)
Clean water and sanitation
Openalex Percentile: Top 25%
Electrochemical Analysis and Applications
1.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.