Development of an LC–ESI–MS/MS Method for the Quantification of Tucatinib in K2EDTA Human Plasma and Its Validation

ABSTRACT Aim of the work is to present a simple LC–ESI–MS/MS approach for a sensitive, specific, and quantitative determination of tucatinib in human K2EDTA plasma. During the retention period of tucatinib and internal standard erlotinib, there was no discernible interference from the endogenous peak. No matrix impact was seen in the test samples and was stable throughout conditions exposed; moreover, recoveries were accurate across the whole calibration curve range. As per the United States Food and Drug Administration bioanalytical technique validation guideline, the LC–MS/MS method was validated in terms of accuracy, linearity, precision, specificity, stability, dilution integrity, extraction recoveries, selectivity, and matrix effect. Linearity and a high r 2 value (>0.99) characterize the calibration curve, which spans 141.5–5660 ng/mL. The intra‐batch accuracy was within −8.45%–5.68% relative error and the precision was within 3.13%–4.91%. The inter‐batch accuracy was within −5.25%–4.64% relative error and the precision was within 3.34%–4.95%. In conclusion, a new approach to evaluating tucatinib in human K2EDTA plasma has been approved for use in clinical, bioavailability, and bioequivalence investigations, and it may be used to quantify tucatinib.

Authors

Institutions

Publication Details

Journal
Separation Science Plus
Published
2025-08-01
DOI
https://doi.org/10.1002/sscp.70099
Primary Topic
Multiple Myeloma Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an LC–ESI–MS/MS Method for the Quantification of Tucatinib in K2EDTA Human Plasma and Its Validation

Kumaraswamy Gandla, Thota Manasa
Separation Science Plus
Multiple Myeloma Research and Treatments
article

Development of an LC–ESI–MS/MS Method for the Quantification of Tucatinib in K2EDTA Human Plasma and Its Validation

Kumaraswamy Gandla, Thota Manasa
article en

Abstract

ABSTRACT Aim of the work is to present a simple LC–ESI–MS/MS approach for a sensitive, specific, and quantitative determination of tucatinib in human K2EDTA plasma. During the retention period of tucatinib and internal standard erlotinib, there was no discernible interference from the endogenous peak. No matrix impact was seen in the test samples and was stable throughout conditions exposed; moreover, recoveries were accurate across the whole calibration curve range. As per the United States Food and Drug Administration bioanalytical technique validation guideline, the LC–MS/MS method was validated in terms of accuracy, linearity, precision, specificity, stability, dilution integrity, extraction recoveries, selectivity, and matrix effect. Linearity and a high r 2 value (>0.99) characterize the calibration curve, which spans 141.5–5660 ng/mL. The intra‐batch accuracy was within −8.45%–5.68% relative error and the precision was within 3.13%–4.91%. The inter‐batch accuracy was within −5.25%–4.64% relative error and the precision was within 3.34%–4.95%. In conclusion, a new approach to evaluating tucatinib in human K2EDTA plasma has been approved for use in clinical, bioavailability, and bioequivalence investigations, and it may be used to quantify tucatinib.

Separation Science PlusVol. 8(8)
Chaitanya Bharathi Institute of Technology (IN)
Openalex Percentile: Top 75%
Multiple Myeloma Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.