Using a Focused X-Ray Beam for Mapping Sensitivity of a Single Crystal CVD Diamond Detector

This paper presents an in-depth mapping sensitivity study using a focused X-ray beam produced by an X-ray tube and applied to a low purity single crystal diamond sample designated as VS-Ti/Au. More specifically, the study shows the effect of changing the beam size, step displacement, bias polarity, annealing of the device as well as the dose rate (tube current) on the current response of these maps. In addition, the current response of the mapping sensitivity as a function of the bias voltage, and the photocurrent pulse shapes at different points (positions within the sample) as a function of time are also presented in this paper. It is worth highlighting that during the investigations of this paper a chemical vapour deposition (CVD) grown understudy sample was selected due to its special features such as: thin nitrogen lines and substrate area (which can be observed by X-ray mapping). Moreover, the investigations included in this paper illustrate two methods which were utilized to measure the spot diameter (a crucial parameter for sensitivity mapping) when moving the detector in the x–y direction. The first method applies a fluorescent paper and a video camera, while the second method applies stepping over an edge of a silicon PIN diode. The results of applying these two methods showed similar trends of spot diameter (i.e. the intensity increase with the increase of the dose rate), however, the second method (silicon PIN diode) resulted-in higher values. The obtained results provide key insights into the behaviour of single crystal CVD diamond detector under X-ray exposure. This is especially important as X-ray exposure sees use in radiotherapeutic applications, small field and online dosimetry, along with medical imaging and beam monitoring in both accelerators and synchrotron radiation facilities.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei Letters
Published
2025-08-01
DOI
https://doi.org/10.1134/s1547477125700773
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using a Focused X-Ray Beam for Mapping Sensitivity of a Single Crystal CVD Diamond Detector

Mohamed A.E. Abdel‐Rahman, Atef El‐Taher, A. Lohstroh, Yasser Alzamil et al.
Physics of Particles and Nuclei Letters
Diamond and Carbon-based Materials Research
article

Using a Focused X-Ray Beam for Mapping Sensitivity of a Single Crystal CVD Diamond Detector

Mohamed A.E. Abdel‐Rahman, Atef El‐Taher, A. Lohstroh, Yasser Alzamil, Mohammad Alobaid, Mohamed Y.M. Mohsen
article en

Abstract

This paper presents an in-depth mapping sensitivity study using a focused X-ray beam produced by an X-ray tube and applied to a low purity single crystal diamond sample designated as VS-Ti/Au. More specifically, the study shows the effect of changing the beam size, step displacement, bias polarity, annealing of the device as well as the dose rate (tube current) on the current response of these maps. In addition, the current response of the mapping sensitivity as a function of the bias voltage, and the photocurrent pulse shapes at different points (positions within the sample) as a function of time are also presented in this paper. It is worth highlighting that during the investigations of this paper a chemical vapour deposition (CVD) grown understudy sample was selected due to its special features such as: thin nitrogen lines and substrate area (which can be observed by X-ray mapping). Moreover, the investigations included in this paper illustrate two methods which were utilized to measure the spot diameter (a crucial parameter for sensitivity mapping) when moving the detector in the x–y direction. The first method applies a fluorescent paper and a video camera, while the second method applies stepping over an edge of a silicon PIN diode. The results of applying these two methods showed similar trends of spot diameter (i.e. the intensity increase with the increase of the dose rate), however, the second method (silicon PIN diode) resulted-in higher values. The obtained results provide key insights into the behaviour of single crystal CVD diamond detector under X-ray exposure. This is especially important as X-ray exposure sees use in radiotherapeutic applications, small field and online dosimetry, along with medical imaging and beam monitoring in both accelerators and synchrotron radiation facilities.

Physics of Particles and Nuclei LettersVol. 22(4)
Al-Azhar University (EG), University of Surrey (GB), University of Ha'il (SA), Military Technical College (EG)
Affordable and clean energy
Openalex Percentile: Top 85%
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.