Studying the Diffuse Reflection of Light from the Mirror of the TUS Detector
The diffuse reflection of light from the surface of the fluorescence detector mirror can distort the interpretation of data. Therefore, it is necessary to estimate the diffuse reflection factor from the surface of the main mirror of the detector. A method of measuring diffuse reflection by comparison with a test object has been applied and the diffuse reflection factor of the TUS mirror prototype has been measured. The value of the diffuse reflection factor rd = 0.41 ± 0.19% will be used to correct the data interpretation methodology.
Authors
- L. G. Tkachev
- A. A. Grinyuk
- А. В. Блинов (ORCID: https://orcid.org/0000-0002-4701-8633)
- А. Н. Бородин
Institutions
- Joint Institute for Nuclear Research (RU)
Publication Details
- Journal
- Physics of Particles and Nuclei Letters
- Published
- 2025-08-01
- DOI
- https://doi.org/10.1134/s1547477125700797
- Primary Topic
- Spectroscopy and Laser Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00