Effect of Cu and Ag Content on the Electrochemical Performance of Fe40Al Intermetallic Alloy in Artificial Saliva

This study investigates the effect of copper (Cu) and silver (Ag) additions on the electrochemical behavior of the Fe40Al intermetallic alloy in artificial saliva, aiming to evaluate its potential for biomedical applications such as dental implants. Alloys with varying concentrations of Ag (0.5, 1.0, and 3.0 wt%) and Cu (1.0, 3.0, and 5.0 wt%) were synthesized and exposed to a biomimetic electrolyte simulating oral conditions. Electrochemical techniques, including open circuit potential (OCP), linear polarization resistance (LPR), potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS), were employed to assess corrosion performance. Results show that unmodified Fe40Al exhibits good corrosion resistance, attributed to the formation of a stable passive oxide layer. The addition of Cu, particularly at 3.0 wt%, significantly improved corrosion resistance, yielding lower corrosion current densities and higher polarization resistance and charge transfer resistance values, surpassing even 316L stainless steel in some metrics. Conversely, Ag additions led to a degradation of corrosion resistance, especially at 3.0 wt%, due to microstructural changes and the formation of metallic Ag precipitates, AgSCN, and galvanic cells, which promoted localized corrosion. EIS results revealed that Cu- and Ag-modified alloys developed less homogeneous and less protective passive layers over time, as indicated by increased double-layer capacitance (Cdl) and reduced constant phase element exponent (ndl) values. Overall, the Fe40Al alloy shows intrinsic corrosion resistance in simulated physiological environments, and Cu additions can enhance this performance under controlled conditions. However, Ag additions negatively affect the protective behavior of the passive layer. These findings offer critical insight into the design of Fe-Al-based biomaterials for dental or biomedical applications where corrosion resistance and electrochemical stability are paramount.

Authors

Institutions

Publication Details

Journal
Metals
Published
2025-08-11
DOI
https://doi.org/10.3390/met15080899
Citations
1
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Cu and Ag Content on the Electrochemical Performance of Fe40Al Intermetallic Alloy in Artificial Saliva

Cinthya Dinorah Arrieta-González, J. Porcayo-Calderón, J.D. Olivas, José Luis Reyes-Barragán et al.
1 citations
Metals
Corrosion Behavior and Inhibition
0.52
article

Effect of Cu and Ag Content on the Electrochemical Performance of Fe40Al Intermetallic Alloy in Artificial Saliva

Cinthya Dinorah Arrieta-González, J. Porcayo-Calderón, J.D. Olivas, José Luis Reyes-Barragán, Jose Gonzalo Gonzalez-Rodriguez, J.G. Chacón-Nava, R.A. Rodríguez-Diaz
article en
1 citations

Abstract

This study investigates the effect of copper (Cu) and silver (Ag) additions on the electrochemical behavior of the Fe40Al intermetallic alloy in artificial saliva, aiming to evaluate its potential for biomedical applications such as dental implants. Alloys with varying concentrations of Ag (0.5, 1.0, and 3.0 wt%) and Cu (1.0, 3.0, and 5.0 wt%) were synthesized and exposed to a biomimetic electrolyte simulating oral conditions. Electrochemical techniques, including open circuit potential (OCP), linear polarization resistance (LPR), potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS), were employed to assess corrosion performance. Results show that unmodified Fe40Al exhibits good corrosion resistance, attributed to the formation of a stable passive oxide layer. The addition of Cu, particularly at 3.0 wt%, significantly improved corrosion resistance, yielding lower corrosion current densities and higher polarization resistance and charge transfer resistance values, surpassing even 316L stainless steel in some metrics. Conversely, Ag additions led to a degradation of corrosion resistance, especially at 3.0 wt%, due to microstructural changes and the formation of metallic Ag precipitates, AgSCN, and galvanic cells, which promoted localized corrosion. EIS results revealed that Cu- and Ag-modified alloys developed less homogeneous and less protective passive layers over time, as indicated by increased double-layer capacitance (Cdl) and reduced constant phase element exponent (ndl) values. Overall, the Fe40Al alloy shows intrinsic corrosion resistance in simulated physiological environments, and Cu additions can enhance this performance under controlled conditions. However, Ag additions negatively affect the protective behavior of the passive layer. These findings offer critical insight into the design of Fe-Al-based biomaterials for dental or biomedical applications where corrosion resistance and electrochemical stability are paramount.

MetalsVol. 15(8)
Universidad de Guadalajara (MX), Universidad de Sonora (MX), Tecnológico Nacional de México (MX), Centro de Investigación en Materiales Avanzados (MX), Instituto Tecnológico de Zacatepec, Universidad Autónoma del Estado de Morelos (MX), Tecnológico de Monterrey (MX)
Openalex Percentile: Top 34%
Corrosion Behavior and Inhibition
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.