Vibrational spectroscopy of urine combined with support vector machine for lupus nephritis diagnosis research

Lupus nephritis (LN) is one of the most common and serious organ manifestations of systemic lupus erythematosus (SLE), with a poor long-term prognosis and a complex diagnostic process, therefore it is important to find a simple, rapid and non-invasive method for the diagnosis of LN. This study investigated the feasibility of using surface-enhanced Raman spectroscopy (SERS) and Fourier Transform Infrared (FT-IR) spectroscopy of urine samples to classify healthy volunteers and LN patients. SERS and FT-IR data of urine samples were obtained from 100 LN patients and 100 healthy volunteers. To verify the stability of the classification algorithm, 50 independent experiments were conducted. In each experiment, the dataset was randomly divided and a classification model was established using the support vector machine (SVM) algorithm (linear kernel function). Meanwhile, it was compared with four other common classification algorithms and the results showed that SVM model had the best effect. The average classification accuracy of SERS and FT-IR spectra combined with SVM model for 50 independent experiments reached 96.97 % and 92.77 %, respectively. In addition, the features of SERS and FT-IR were spliced and then combined with SVM model for classification, corresponding to an average classification accuracy of 97.63 %. Subsequently, genetic algorithm was used to perform feature selection on the spliced features, and the 16 selected features were also input into SVM model, with an average classification accuracy of 99.47 % over 50 independent experiments. Therefore, urine vibrational spectroscopy combined with SVM model has great potential in the diagnosis of lupus nephritis. • SERS and FT-IR techniques have great potential in the diagnosis of lupus nephritis. • Urine samples were used to classify lupus nephritis patients and healthy controls. • The classification effect is improved after feature fusion and feature selection of spectra.

Authors

Institutions

Publication Details

Journal
Vibrational Spectroscopy
Published
2025-08-11
DOI
https://doi.org/10.1016/j.vibspec.2025.103845
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vibrational spectroscopy of urine combined with support vector machine for lupus nephritis diagnosis research

Xiaojing Sun, Longfei Yin, Ying Tan, Yu Du et al.
Vibrational Spectroscopy
Spectroscopy Techniques in Biomedical and Chemical Research
article

Vibrational spectroscopy of urine combined with support vector machine for lupus nephritis diagnosis research

Xiaojing Sun, Longfei Yin, Ying Tan, Yu Du, Guohua Wu, Zhaonan You, Bingqian Ran
article en

Abstract

Lupus nephritis (LN) is one of the most common and serious organ manifestations of systemic lupus erythematosus (SLE), with a poor long-term prognosis and a complex diagnostic process, therefore it is important to find a simple, rapid and non-invasive method for the diagnosis of LN. This study investigated the feasibility of using surface-enhanced Raman spectroscopy (SERS) and Fourier Transform Infrared (FT-IR) spectroscopy of urine samples to classify healthy volunteers and LN patients. SERS and FT-IR data of urine samples were obtained from 100 LN patients and 100 healthy volunteers. To verify the stability of the classification algorithm, 50 independent experiments were conducted. In each experiment, the dataset was randomly divided and a classification model was established using the support vector machine (SVM) algorithm (linear kernel function). Meanwhile, it was compared with four other common classification algorithms and the results showed that SVM model had the best effect. The average classification accuracy of SERS and FT-IR spectra combined with SVM model for 50 independent experiments reached 96.97 % and 92.77 %, respectively. In addition, the features of SERS and FT-IR were spliced and then combined with SVM model for classification, corresponding to an average classification accuracy of 97.63 %. Subsequently, genetic algorithm was used to perform feature selection on the spliced features, and the 16 selected features were also input into SVM model, with an average classification accuracy of 99.47 % over 50 independent experiments. Therefore, urine vibrational spectroscopy combined with SVM model has great potential in the diagnosis of lupus nephritis. • SERS and FT-IR techniques have great potential in the diagnosis of lupus nephritis. • Urine samples were used to classify lupus nephritis patients and healthy controls. • The classification effect is improved after feature fusion and feature selection of spectra.

Vibrational SpectroscopyVol. 140
Beijing University of Posts and Telecommunications (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Ministry of Education (RO)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 85%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.