Improved positioning criterion and imaging scheme of deep UV planar laser-induced fluorescence technology

In summary, we have developed a physical model to describe the evolution of the nitric oxide-based planar laser-induced fluorescence technology (NO-PLIF) signal in a high-enthalpy wind tunnel and analyzed the factors that affect the contrast of fluorescent stripes obtained from two successive ultraviolet (UV) laser exposures. Based on this, we improved the flow velocity calculation algorithm with a centroiding positioning criterion, which is more accurate for flows with velocities of above 3 km/s and has better adaptability to background noises compared to the conventional peak value positioning criterion. Meanwhile, we have identified that a shortened frame interval is an effective means to improve the measurement accuracy of a hypervelocity flow, where a dual-frame high-speed UV imaging system is developed with a frame interval that is two orders of magnitude shorter than existing UV cameras. Consequently, transient N<sub>2</sub> flows with velocities ranging from 3.2 to 5.2 km/s were successfully measured. Further efforts will pay on extending the proposed positioning criterion to the cross-correlation algorithm for higher velocity measurement accuracy.

Authors

Institutions

Publication Details

Journal
iScience
Published
2025-08-11
DOI
https://doi.org/10.1016/j.isci.2025.113333
Primary Topic
Laser Design and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved positioning criterion and imaging scheme of deep UV planar laser-induced fluorescence technology

Wenxiong Lin, WU Li-xia, Haizhou Huang, Hongchun Wu et al.
iScience
Laser Design and Applications
article

Improved positioning criterion and imaging scheme of deep UV planar laser-induced fluorescence technology

Wenxiong Lin, WU Li-xia, Haizhou Huang, Hongchun Wu, Zhi Zhang, Shutao Dai
article en

Abstract

In summary, we have developed a physical model to describe the evolution of the nitric oxide-based planar laser-induced fluorescence technology (NO-PLIF) signal in a high-enthalpy wind tunnel and analyzed the factors that affect the contrast of fluorescent stripes obtained from two successive ultraviolet (UV) laser exposures. Based on this, we improved the flow velocity calculation algorithm with a centroiding positioning criterion, which is more accurate for flows with velocities of above 3 km/s and has better adaptability to background noises compared to the conventional peak value positioning criterion. Meanwhile, we have identified that a shortened frame interval is an effective means to improve the measurement accuracy of a hypervelocity flow, where a dual-frame high-speed UV imaging system is developed with a frame interval that is two orders of magnitude shorter than existing UV cameras. Consequently, transient N<sub>2</sub> flows with velocities ranging from 3.2 to 5.2 km/s were successfully measured. Further efforts will pay on extending the proposed positioning criterion to the cross-correlation algorithm for higher velocity measurement accuracy.

iScienceVol. 28(9)
Fujian Normal University (CN), Fujian Institute of Research on the Structure of Matter (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 81%
Laser Design and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.