A Helical Reconstruction Network for Multi-Source Static CT

Nanovision static CT is an innovative CT scanning technique that features the arrangement of the X-ray source array and detector array on two parallel planes with a consistent offset. This configuration significantly enhances temporal resolution compared to conventional CT, providing particular advantages for dynamic organ imaging and low-dose imaging applications. However, it also introduces cone angle and sparse angle artifacts during helical scanning. To address this, this paper proposes a novel theoretical analysis framework to systematically analyze the artifact generation mechanism of the traditional FDK algorithm in this scenario. Through numerical solutions and data superposition, we are able to attribute the causes of artifacts for the first time to two types of data incompleteness issues arising from the lack of cone angle data and insufficient sparse angular sampling. Building on these insights, we propose an innovative dual-module collaborative reconstruction network. First, we introduce the Helical Bi-directional xFDK algorithm (HbixFDK), which employs a limited-angle weighted compensation strategy to mitigate data incompleteness in the cone angle region. Next, we develop the attention-based Helical FISTA network (HFISTA-Net), which utilizes the output from HbixFDK as the initial reconstruction to effectively suppress sparse sampling artifacts. Extensive experiments conducted on the TCIA dataset and clinical static CT scans demonstrate that our proposed method significantly reduces both cone angle and sparse angle artifacts in static CT helical scanning. The approach achieves rapid and high-precision helical reconstruction, showcasing superior accuracy and computational efficiency.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Computational Imaging
Published
2025-01-01
DOI
https://doi.org/10.1109/tci.2025.3597449
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Helical Reconstruction Network for Multi-Source Static CT

C Ma, Yunxiang Li, Shouhua Luo, Kaiwen Tan
1 citations
IEEE Transactions on Computational Imaging
Advanced X-ray and CT Imaging
0.67
article

A Helical Reconstruction Network for Multi-Source Static CT

C Ma, Yunxiang Li, Shouhua Luo, Kaiwen Tan
article en
1 citations

Abstract

Nanovision static CT is an innovative CT scanning technique that features the arrangement of the X-ray source array and detector array on two parallel planes with a consistent offset. This configuration significantly enhances temporal resolution compared to conventional CT, providing particular advantages for dynamic organ imaging and low-dose imaging applications. However, it also introduces cone angle and sparse angle artifacts during helical scanning. To address this, this paper proposes a novel theoretical analysis framework to systematically analyze the artifact generation mechanism of the traditional FDK algorithm in this scenario. Through numerical solutions and data superposition, we are able to attribute the causes of artifacts for the first time to two types of data incompleteness issues arising from the lack of cone angle data and insufficient sparse angular sampling. Building on these insights, we propose an innovative dual-module collaborative reconstruction network. First, we introduce the Helical Bi-directional xFDK algorithm (HbixFDK), which employs a limited-angle weighted compensation strategy to mitigate data incompleteness in the cone angle region. Next, we develop the attention-based Helical FISTA network (HFISTA-Net), which utilizes the output from HbixFDK as the initial reconstruction to effectively suppress sparse sampling artifacts. Extensive experiments conducted on the TCIA dataset and clinical static CT scans demonstrate that our proposed method significantly reduces both cone angle and sparse angle artifacts in static CT helical scanning. The approach achieves rapid and high-precision helical reconstruction, showcasing superior accuracy and computational efficiency.

IEEE Transactions on Computational ImagingVol. 11
InferVision (China) (CN), Southeast University (CN)
National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 28%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.