A Gamma-Ray Imaging Detector Using Position-Sensitive SiPM Coupled to GAGG:Ce Scintillator Array

Position-sensitive scintillator detectors are critical components in coded-aperture imaging and Compton imaging systems. Improving the position resolution and energy resolution of the detector is crucial for system performance. Traditional position sensitive scintillator detectors are constrained by the size of photoelectric readout devices and the number of readout channels, making it difficult to achieve both high position resolution and energy resolution at a low cost. This study presents a novel gamma-ray imaging detector that overcomes the traditional trade-off between position resolution, energy resolution, and cost. Using a high-resolution cerium-doped gadolinium aluminum gallium garnet (GAGG:Ce) scintillator array (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.5\times 0.5\times 5$ </tex-math></inline-formula> mm pixels) read out by a position-sensitive silicon photomultiplier (PS-SiPM) through its four anodes, we achieved direct position reconstruction without the use of a light-sharing technique. A <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">137</sup>Cs source was used to test the performance of this imaging detector. It demonstrated a clear segmentation of a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10\times 10$ </tex-math></inline-formula> array with 7.2% [full-width-at-half-maximum (FWHM)] energy resolution for 662 keV, significantly simplifying the design of electronic readout systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2025-08-11
DOI
https://doi.org/10.1109/tns.2025.3597733
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Gamma-Ray Imaging Detector Using Position-Sensitive SiPM Coupled to GAGG:Ce Scintillator Array

Chengshuai Tian, Jian Yang, Chuanhao Hu, Fuquan Chen et al.
IEEE Transactions on Nuclear Science
Radiation Detection and Scintillator Technologies
article

A Gamma-Ray Imaging Detector Using Position-Sensitive SiPM Coupled to GAGG:Ce Scintillator Array

Chengshuai Tian, Jian Yang, Chuanhao Hu, Fuquan Chen, Honglin Zhao, Guoqiang Zeng
article en

Abstract

Position-sensitive scintillator detectors are critical components in coded-aperture imaging and Compton imaging systems. Improving the position resolution and energy resolution of the detector is crucial for system performance. Traditional position sensitive scintillator detectors are constrained by the size of photoelectric readout devices and the number of readout channels, making it difficult to achieve both high position resolution and energy resolution at a low cost. This study presents a novel gamma-ray imaging detector that overcomes the traditional trade-off between position resolution, energy resolution, and cost. Using a high-resolution cerium-doped gadolinium aluminum gallium garnet (GAGG:Ce) scintillator array (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.5\times 0.5\times 5$ </tex-math></inline-formula> mm pixels) read out by a position-sensitive silicon photomultiplier (PS-SiPM) through its four anodes, we achieved direct position reconstruction without the use of a light-sharing technique. A <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">137</sup>Cs source was used to test the performance of this imaging detector. It demonstrated a clear segmentation of a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$10\times 10$ </tex-math></inline-formula> array with 7.2% [full-width-at-half-maximum (FWHM)] energy resolution for 662 keV, significantly simplifying the design of electronic readout systems.

IEEE Transactions on Nuclear ScienceVol. 72(9)
Chengdu University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 73%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.