A Robot-Assisted Optical Coherence Tomography (OCT) System for Inspecting Inner Wall Defects in Nonspherical Lumens

Inspecting defects in nonspherical lumens is challenging due to occlusion and depth variation, hindering complete point cloud data reconstruction. This article introduces a robot-assisted optical coherence tomography (OCT) system for conducting reconstruction and inner wall defects detection tasks in nonspherical lumens, leveraging robotic arm’s flexibility. Unlike image sensors, the developed OCT probe collects data via rotating scanning, complicating hand–eye calibration due to the lack of calibration features and coordinate drift in rotating probe. To address this, a decoupled hand–eye calibration method was proposed, utilizing iterative sphere-center fitting to improve accuracy in limited features and address coordinate drift problem. Moreover, OCT-acquired point clouds often include noise, artifacts, and exhibit anisotropy, complicating the detection of subtle defects. To overcome this challenge, we proposed a geometry-aware detection method based on local normal estimation to inspect defects in nonspherical lumens. Experimental results demonstrated a 55.2% improvement in hand–eye calibration with the proposed method, achieving a sphere fitting error of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$12.4~{\mu }$ </tex-math></inline-formula>m compared to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$27.7~{\mu }$ </tex-math></inline-formula>m in the traditional method. The method showed an average accuracy of 87.9% in detecting micrometer-level lumen defects, outperforming the state-of-the-art (SOTA) anomaly detection method (3D-ST), which achieved an average accuracy of 62.2%.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3597676
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Robot-Assisted Optical Coherence Tomography (OCT) System for Inspecting Inner Wall Defects in Nonspherical Lumens

Zhongxing Wang, Wangping Xiong, J. Ye, Yu Sun et al.
IEEE Transactions on Instrumentation and Measurement
Coronary Interventions and Diagnostics
article

A Robot-Assisted Optical Coherence Tomography (OCT) System for Inspecting Inner Wall Defects in Nonspherical Lumens

Zhongxing Wang, Wangping Xiong, J. Ye, Yu Sun, Jiancai Huang, Yurui Pu, Xingjian Liu, Xiaolong Yu, R. Zou
article en

Abstract

Inspecting defects in nonspherical lumens is challenging due to occlusion and depth variation, hindering complete point cloud data reconstruction. This article introduces a robot-assisted optical coherence tomography (OCT) system for conducting reconstruction and inner wall defects detection tasks in nonspherical lumens, leveraging robotic arm’s flexibility. Unlike image sensors, the developed OCT probe collects data via rotating scanning, complicating hand–eye calibration due to the lack of calibration features and coordinate drift in rotating probe. To address this, a decoupled hand–eye calibration method was proposed, utilizing iterative sphere-center fitting to improve accuracy in limited features and address coordinate drift problem. Moreover, OCT-acquired point clouds often include noise, artifacts, and exhibit anisotropy, complicating the detection of subtle defects. To overcome this challenge, we proposed a geometry-aware detection method based on local normal estimation to inspect defects in nonspherical lumens. Experimental results demonstrated a 55.2% improvement in hand–eye calibration with the proposed method, achieving a sphere fitting error of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$12.4~{\mu }$ </tex-math></inline-formula>m compared to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$27.7~{\mu }$ </tex-math></inline-formula>m in the traditional method. The method showed an average accuracy of 87.9% in detecting micrometer-level lumen defects, outperforming the state-of-the-art (SOTA) anomaly detection method (3D-ST), which achieved an average accuracy of 62.2%.

IEEE Transactions on Instrumentation and MeasurementVol. 74
University of Toronto (CA), Dalian University of Technology (CN)
Liaoning Revitalization Talents Program, Natural Science Foundation for Young Scientists of Shanxi Province, National Key Research and Development Program of China
Openalex Percentile: Top 66%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.