Levofloxacin determination in urine by photoluminescence spectroelectrochemistry

• Novel Photoluminescence-spectroelectrochemistry cell for screen-printed electrodes. • Photoluminescence-spectroelectrochemistry determination of levofloxacin. • Quantification of levofloxacin in tap water samples in the limit of detection range. • Determination of levofloxacin in urine samples without interfering uric acid. Photoluminescent spectroelectrochemistry (PL-SEC) has scarcely been used for quantitative purposes. The present work demonstrates the effectiveness of PL-SEC in addressing real-world analytical challenges through the quantitative analysis of the antibacterial drug levofloxacin. This study examines the behavior of levofloxacin in samples containing potentially interfering substances, with the aim of simulating the conditions encountered in real scenarios. Fluorescence remains among the most specific techniques in qualitative and quantitative analysis. Here, the evolution of levofloxacin fluorescence spectra recorded during a PL-SEC experiment are found to be very useful for identifying and quantifying levofloxacin in tap water and urine samples. With this objective, a novel PL-SEC cell has been designed, constructed and tested that simplifies significantly the performance of these kind of experiments and favors the reproducibility in analytical determinations. The use of appropriate calibration models provided by PL-SEC experiments has facilitated the determination of levofloxacin. This outcome validates the efficacy and the suitability of this multi-response technique for the accurate measurement of this molecule, particularly in context involving low concentrations and complex samples. The proposed methodology has been demonstrated to be very simple, sensitive reaching a limit of detection of 0.17 µM, and highly reproducible. For electrochemical determinations the reproducibility is less than 7.5 % and for fluorescent quantification, it is below 3.5 %. The low data dispersion should also be highlighted, as evidenced by %RSD values below 7 %, thus making it a suitable candidate for use as a reference method in quantitative analysis.

Authors

Institutions

Publication Details

Journal
Electrochimica Acta
Published
2025-08-10
DOI
https://doi.org/10.1016/j.electacta.2025.147123
Citations
2
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
2.79

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Levofloxacin determination in urine by photoluminescence spectroelectrochemistry

Álvaro Colina, F. Javier del Campo, Natalia Pérez‐Sánchez, Aránzazu Heras et al.
2 citations
Electrochimica Acta
Antibiotics Pharmacokinetics and Efficacy
2.79
article

Levofloxacin determination in urine by photoluminescence spectroelectrochemistry

Álvaro Colina, F. Javier del Campo, Natalia Pérez‐Sánchez, Aránzazu Heras, Luis Romay, Fabiola Olmo, Pello Núñez-Marinero
article en
2 citations

Abstract

• Novel Photoluminescence-spectroelectrochemistry cell for screen-printed electrodes. • Photoluminescence-spectroelectrochemistry determination of levofloxacin. • Quantification of levofloxacin in tap water samples in the limit of detection range. • Determination of levofloxacin in urine samples without interfering uric acid. Photoluminescent spectroelectrochemistry (PL-SEC) has scarcely been used for quantitative purposes. The present work demonstrates the effectiveness of PL-SEC in addressing real-world analytical challenges through the quantitative analysis of the antibacterial drug levofloxacin. This study examines the behavior of levofloxacin in samples containing potentially interfering substances, with the aim of simulating the conditions encountered in real scenarios. Fluorescence remains among the most specific techniques in qualitative and quantitative analysis. Here, the evolution of levofloxacin fluorescence spectra recorded during a PL-SEC experiment are found to be very useful for identifying and quantifying levofloxacin in tap water and urine samples. With this objective, a novel PL-SEC cell has been designed, constructed and tested that simplifies significantly the performance of these kind of experiments and favors the reproducibility in analytical determinations. The use of appropriate calibration models provided by PL-SEC experiments has facilitated the determination of levofloxacin. This outcome validates the efficacy and the suitability of this multi-response technique for the accurate measurement of this molecule, particularly in context involving low concentrations and complex samples. The proposed methodology has been demonstrated to be very simple, sensitive reaching a limit of detection of 0.17 µM, and highly reproducible. For electrochemical determinations the reproducibility is less than 7.5 % and for fluorescent quantification, it is below 3.5 %. The low data dispersion should also be highlighted, as evidenced by %RSD values below 7 %, thus making it a suitable candidate for use as a reference method in quantitative analysis.

Electrochimica ActaVol. 539
Ikerbasque (ES), Basque Center for Materials, Applications and Nanostructures (ES), Universidad de Burgos (ES)
Ministerio de Ciencia, Innovación y Universidades, Ministerio de Ciencia e Innovación, Junta de Castilla y León, European Regional Development Fund, Agencia Estatal de Investigación, European Social Fund
Zero hunger
Openalex Percentile: Top 9%
Antibiotics Pharmacokinetics and Efficacy
2.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.