Insulation Degradation Assessment of 10 kV XLPE Cable by High-Voltage-Impendence Measurement

Capacitance or impedance changes are key indicators for assessing cable insulation degradation. A test circuit was developed to measure capacitive reactance under high voltage at varying frequencies, considering the much higher resistance of the insulation layer compared to its capacitive impedance. Results show that lower frequencies lead to reduced current and increased phase angle. Aging tests at 135°C revealed a decrease in capacitance and corresponding changes in impedance and phase angle. To ensure accurate phase angle measurement, the protective resistance was adjusted based on capacitance variations. The proposed method demonstrates preliminary feasibility for detecting insulation degradation in 10 kV XLPE cables.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/netps65392.2025.11102073
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insulation Degradation Assessment of 10 kV XLPE Cable by High-Voltage-Impendence Measurement

Zhuozhan Han, Yue Xie, Jiasheng Huang, Min Xu
1 links
High voltage insulation and dielectric phenomena
article

Insulation Degradation Assessment of 10 kV XLPE Cable by High-Voltage-Impendence Measurement

Zhuozhan Han, Yue Xie, Jiasheng Huang, Min Xu
article en

Abstract

Capacitance or impedance changes are key indicators for assessing cable insulation degradation. A test circuit was developed to measure capacitive reactance under high voltage at varying frequencies, considering the much higher resistance of the insulation layer compared to its capacitive impedance. Results show that lower frequencies lead to reduced current and increased phase angle. Aging tests at 135°C revealed a decrease in capacitance and corresponding changes in impedance and phase angle. To ensure accurate phase angle measurement, the protective resistance was adjusted based on capacitance variations. The proposed method demonstrates preliminary feasibility for detecting insulation degradation in 10 kV XLPE cables.

Guangdong Polytechnic Normal University (CN), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Openalex Percentile: Top 85%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Insulation Degradation Assessment of 10 kV XLPE Cable by High-Voltage-Impendence Measurement — Zhuozhan Han, Yue Xie, et al. · (2025) | TGRS Research Map | TGRS