Effect of screw access hole on the fracture load of implant-supported monolithic translucent zirconia crowns after mechanical cycling

This study evaluated the effects of screw hole and preparation techniques on the fracture resistance of implant-supported translucent zirconia crowns after mechanical cycling. Forty crowns were divided into four groups of 10: CNH (cement-retained with no screw access hole) for the control, HBS (hole prepared before dense sintering), HAS (hole manually prepared after sintering), and HRS (hole manually prepared undergo resintered). All crowns survived 360,000 cycles with a peak force of 300 N at 10 Hz. Fracture resistance assessments indicated that the HBS technique exhibited the highest resistance, with CNS demonstrating the lowest. However, statistical analyses (Kruskal–Wallis and Mann–Whitney U tests) revealed no significant differences between them. SEM fractographic analysis indicated that screw hole preparation techniques could influence fracture patterns and failure initiation in zirconia crowns.

Authors

Institutions

Publication Details

Journal
Advances in Applied Ceramics Structural Functional and Bioceramics
Published
2025-06-30
DOI
https://doi.org/10.1177/17436753251352677
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of screw access hole on the fracture load of implant-supported monolithic translucent zirconia crowns after mechanical cycling

Shusen Zhang, Mo-yu Xu, Jianguo Yi, Wei Deng et al.
Advances in Applied Ceramics Structural Functional and Bioceramics
Dental materials and restorations
article

Effect of screw access hole on the fracture load of implant-supported monolithic translucent zirconia crowns after mechanical cycling

Shusen Zhang, Mo-yu Xu, Jianguo Yi, Wei Deng, Lingjie Zheng, Xinkun Zhao
article en

Abstract

This study evaluated the effects of screw hole and preparation techniques on the fracture resistance of implant-supported translucent zirconia crowns after mechanical cycling. Forty crowns were divided into four groups of 10: CNH (cement-retained with no screw access hole) for the control, HBS (hole prepared before dense sintering), HAS (hole manually prepared after sintering), and HRS (hole manually prepared undergo resintered). All crowns survived 360,000 cycles with a peak force of 300 N at 10 Hz. Fracture resistance assessments indicated that the HBS technique exhibited the highest resistance, with CNS demonstrating the lowest. However, statistical analyses (Kruskal–Wallis and Mann–Whitney U tests) revealed no significant differences between them. SEM fractographic analysis indicated that screw hole preparation techniques could influence fracture patterns and failure initiation in zirconia crowns.

Advances in Applied Ceramics Structural Functional and BioceramicsVol. 124(3-5)
Huaihua University (CN)
Natural Science Foundation of Hunan Province
Openalex Percentile: Top 78%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of screw access hole on the fracture load of implant-supported monolithic translucent zirconia crowns after mechanical cycling — Shusen Zhang, Mo-yu Xu, et al. · Advances in Applied Ceramics Structural Functional and Bioceramics (2025) | TGRS Research Map | TGRS