Optimizing Knee MRI: Diagnostic Performance of a 3D PDW SPAIR-Based Short Protocol

Objectives: This study aimed to evaluate the usefulness of a short magnetic resonance (MR) protocol for knee evaluation, using 3D PDW SPAIR sequences compared with traditional 2D ones. Methods: A prospective analysis included 76 patients with knee pain. MR was performed using a 1.5 T scanner. The standard protocol consisted of multiplanar 2D proton density-weighted (PDW) SPectral Attenuated Inversion Recovery (SPAIR) and additional T1-weighted (T1W) and T2-weighted (T2W) sequences, with a total acquisition time of 17 min. The simulated short protocol included a 3D PDW SPAIR sequence with isotropic voxels and a slice thickness of 0.6 mm, coronal T1W, and gradient echo (GRE) axial sequences, with a total acquisition time of 9 min. Two radiologists independently reviewed images and collected pathological processes. Results: The 3D PDW SPAIR sequence demonstrated a significantly higher subjective image quality compared to standard 2D sequences [κ = 0.712 (p < 0.001) vs. κ = 0.144 (p = 0.63); p < 0.001]. Artifacts were not significantly different between the two protocols (p = 0.201). Qualitative assessments showed superior ratings for 3D images (excellent quality: 72.4% vs. 26.3% for 3D and 2D, respectively; p < 0.001). Diagnostic performance was comparable between the two protocols for ACL injuries, medial and lateral collateral ligament injuries, and chondropathies. Three-dimensional sequences were more effective in detecting medial meniscal injuries (p < 0.001), particularly radial and complex tears, likely due to higher spatial resolution and multiplanar reconstruction capability. Conclusions: The 3D PDW SPAIR sequence offers advantages in knee MRI study, including improved image quality, reduced acquisition time, and superior detection of meniscal injuries.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-08-12
DOI
https://doi.org/10.3390/app15168870
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Knee MRI: Diagnostic Performance of a 3D PDW SPAIR-Based Short Protocol

Maria Ragusi, Cesare Maino, P. Allegranza, Marco Turati et al.
Applied Sciences
Advanced MRI Techniques and Applications
article

Optimizing Knee MRI: Diagnostic Performance of a 3D PDW SPAIR-Based Short Protocol

Maria Ragusi, Cesare Maino, P. Allegranza, Marco Turati, Serena Pellegatta, Davide Ippolito, Davide Gandola, Cammillo Talei Franzesi, Rocco Corso, Marco Pinnizzotto
article en

Abstract

Objectives: This study aimed to evaluate the usefulness of a short magnetic resonance (MR) protocol for knee evaluation, using 3D PDW SPAIR sequences compared with traditional 2D ones. Methods: A prospective analysis included 76 patients with knee pain. MR was performed using a 1.5 T scanner. The standard protocol consisted of multiplanar 2D proton density-weighted (PDW) SPectral Attenuated Inversion Recovery (SPAIR) and additional T1-weighted (T1W) and T2-weighted (T2W) sequences, with a total acquisition time of 17 min. The simulated short protocol included a 3D PDW SPAIR sequence with isotropic voxels and a slice thickness of 0.6 mm, coronal T1W, and gradient echo (GRE) axial sequences, with a total acquisition time of 9 min. Two radiologists independently reviewed images and collected pathological processes. Results: The 3D PDW SPAIR sequence demonstrated a significantly higher subjective image quality compared to standard 2D sequences [κ = 0.712 (p < 0.001) vs. κ = 0.144 (p = 0.63); p < 0.001]. Artifacts were not significantly different between the two protocols (p = 0.201). Qualitative assessments showed superior ratings for 3D images (excellent quality: 72.4% vs. 26.3% for 3D and 2D, respectively; p < 0.001). Diagnostic performance was comparable between the two protocols for ACL injuries, medial and lateral collateral ligament injuries, and chondropathies. Three-dimensional sequences were more effective in detecting medial meniscal injuries (p < 0.001), particularly radial and complex tears, likely due to higher spatial resolution and multiplanar reconstruction capability. Conclusions: The 3D PDW SPAIR sequence offers advantages in knee MRI study, including improved image quality, reduced acquisition time, and superior detection of meniscal injuries.

Applied SciencesVol. 15(16)
Azienda Ospedaliera San Gerardo (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT), University of Milano-Bicocca (IT)
Good health and well-being
Openalex Percentile: Top 70%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.