Electrocatalytic Hollow AgAu/SiO<sub>2</sub> Sensor for Multi-Matrix Isoproturon Monitoring

This study reports the development and application of an electrochemical sensor based on a glassy carbon electrode (GCE) modified with hollow AgAu nanoshells supported on SiO<sub>2</sub> (AgAu NSs/SiO<sub>2</sub>) and Nafion as a binder. The proposed AgAu NSs/SiO<sub>2</sub>/NF/GCE sensor demonstrated excellent analytical performance for detecting isoproturon (ISO), a persistent environmental contaminant of significant concern. The sensor exhibited a wide linear detection range from 0.75 to 20 μg L<sup>-1</sup>, a low detection limit of 0.011 μg L<sup>-1</sup>, and a quantification limit of 0.037 μg L<sup>-1</sup>, meeting and exceeding regulatory requirements. Differential pulse voltammetry revealed a remarkable 220% increase in peak current response compared to the unmodified electrode, indicating superior electrocatalytic activity. The sensor also demonstrated high repeatability (RSD = 3.28%), reproducibility (RSD = 1.10%), and excellent selectivity with minimal interference from complex matrices. Its applicability was successfully validated in aquaculture water, tomato extract, and human plasma samples, achieving recovery rates ranging from 83.0 to 100.4%. The key contribution of this work is the synthesis of AgAu nanoshells via a galvanic replacement reaction and their integration into an electrochemical sensor, which exhibits enhanced sensitivity, selectivity, and environmental applicability. This novel sensing platform offers a practical, efficient, and versatile tool for ISO monitoring across diverse real-world samples.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-08-12
DOI
https://doi.org/10.1021/acsomega.5c02480
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrocatalytic Hollow AgAu/SiO2 Sensor for Multi-Matrix Isoproturon Monitoring

Antônio Gomes dos Santos Neto, Cristiane Luisa Jost, Marco Aurélio Suller Garcia, Sergio Yesid Gómez González et al.
ACS Omega
Electrochemical sensors and biosensors
article

Electrocatalytic Hollow AgAu/SiO2 Sensor for Multi-Matrix Isoproturon Monitoring

Antônio Gomes dos Santos Neto, Cristiane Luisa Jost, Marco Aurélio Suller Garcia, Sergio Yesid Gómez González, Thenner S. Rodrigues, Rebeca Evahides Yatsuzuka, Camila Silva de Sousa, José Antônio de Oliveira, Felipe Anchieta e Silva
article en

Abstract

This study reports the development and application of an electrochemical sensor based on a glassy carbon electrode (GCE) modified with hollow AgAu nanoshells supported on SiO<sub>2</sub> (AgAu NSs/SiO<sub>2</sub>) and Nafion as a binder. The proposed AgAu NSs/SiO<sub>2</sub>/NF/GCE sensor demonstrated excellent analytical performance for detecting isoproturon (ISO), a persistent environmental contaminant of significant concern. The sensor exhibited a wide linear detection range from 0.75 to 20 μg L<sup>-1</sup>, a low detection limit of 0.011 μg L<sup>-1</sup>, and a quantification limit of 0.037 μg L<sup>-1</sup>, meeting and exceeding regulatory requirements. Differential pulse voltammetry revealed a remarkable 220% increase in peak current response compared to the unmodified electrode, indicating superior electrocatalytic activity. The sensor also demonstrated high repeatability (RSD = 3.28%), reproducibility (RSD = 1.10%), and excellent selectivity with minimal interference from complex matrices. Its applicability was successfully validated in aquaculture water, tomato extract, and human plasma samples, achieving recovery rates ranging from 83.0 to 100.4%. The key contribution of this work is the synthesis of AgAu nanoshells via a galvanic replacement reaction and their integration into an electrochemical sensor, which exhibits enhanced sensitivity, selectivity, and environmental applicability. This novel sensing platform offers a practical, efficient, and versatile tool for ISO monitoring across diverse real-world samples.

ACS OmegaVol. 10(33)
Universidade Federal do Rio de Janeiro (BR), Universidade de São Paulo (BR), Universidade Federal de Santa Catarina (BR), Universidade Federal do Maranhão (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro, Universidade Federal de Santa Catarina
Openalex Percentile: Top 81%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.