QC Test for intensity-modulated X-rays using gafchromic EBT3 film and 2D ion chamber array on a single linac

Accurate dosimetric verification is crucial in intensity-modulated radiotherapy (IMRT) to ensure precise dose delivery to target tissues while sparing surrounding healthy structures. This study aims to compare two widely used dosimetry tools-Gafchromic EBT3 film and the IBA MatriXX 2D ion chamber array-in terms of dose distribution accuracy and spatial resolution. A series of IMRT fields were delivered using an Elekta Synergy Platform linear accelerator, and planar dose distributions were measured using both systems. Gamma index analysis was conducted with 3%/3 mm and 2%/2 mm criteria. Results showed that both systems provided clinically acceptable agreement with planned distributions, although the Gafchromic film exhibited superior spatial resolution. These findings highlight the complementary rolls of film and ion chamber array dosimetry in modern radiotherapy QA.

Authors

Publication Details

Journal
International Journal of Radiology & Radiation Therapy
Published
2025-01-01
DOI
https://doi.org/10.15406/ijrrt.2025.12.00424
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QC Test for intensity-modulated X-rays using gafchromic EBT3 film and 2D ion chamber array on a single linac

Nina Tunçel, Aysun İnal, Kadir Dağ
International Journal of Radiology & Radiation Therapy
Advanced Radiotherapy Techniques
article

QC Test for intensity-modulated X-rays using gafchromic EBT3 film and 2D ion chamber array on a single linac

Nina Tunçel, Aysun İnal, Kadir Dağ
article en

Abstract

Accurate dosimetric verification is crucial in intensity-modulated radiotherapy (IMRT) to ensure precise dose delivery to target tissues while sparing surrounding healthy structures. This study aims to compare two widely used dosimetry tools-Gafchromic EBT3 film and the IBA MatriXX 2D ion chamber array-in terms of dose distribution accuracy and spatial resolution. A series of IMRT fields were delivered using an Elekta Synergy Platform linear accelerator, and planar dose distributions were measured using both systems. Gamma index analysis was conducted with 3%/3 mm and 2%/2 mm criteria. Results showed that both systems provided clinically acceptable agreement with planned distributions, although the Gafchromic film exhibited superior spatial resolution. These findings highlight the complementary rolls of film and ion chamber array dosimetry in modern radiotherapy QA.

International Journal of Radiology & Radiation TherapyVol. 12(3)
Openalex Percentile: Top 73%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

QC Test for intensity-modulated X-rays using gafchromic EBT3 film and 2D ion chamber array on a single linac — Nina Tunçel, Aysun İnal, et al. · International Journal of Radiology & Radiation Therapy (2025) | TGRS Research Map | TGRS