A Comparative Analysis of Functional Outcome of Distal Femur Fractures Treated with Locking Compression Plate Fixation and Non-Locking Plate Fixation

Background: Distal femur fractures represent a significant orthopedic challenge, requiring optimal fixation techniques to restore knee joint function and promote fracture healing. The choice between Locking Compression Plate (LCP) fixation and Non-Locking Plate fixation significantly impacts functional outcomes. Objective: To compare the functional outcomes of distal femur fractures treated with LCP fixation versus Non-Locking Plate fixation, focusing on knee function, fracture union time, range of motion, and post-operative recovery. Methods: A prospective observational study was conducted at Saraswathi Institute of Medical Sciences involving 60 adult patients (aged 18-70 years) with distal femur fractures. Patients were divided into two groups: 30 treated with LCP fixation and 30 with Non-Locking Plate fixation. Fractures were classified using Muller's classification system. Functional outcomes were assessed using the Hospital for Special Surgery (HSS) knee scoring system. Results: The LCP group demonstrated superior functional outcomes with 83.2% achieving excellent knee scores compared to 75.3% in the Non-Locking Plate group (p=0.004). Mean range of motion was significantly higher in the LCP group (111° ± 18.1) compared to the Non-Locking Plate group (92° ± 17.2) (p=0.0001). LCP fixation was preferred for complex fractures (C1, C2, C3 types), while Non-Locking Plates were more commonly used for simpler fractures. Conclusion: LCP fixation provides superior functional outcomes compared to Non-Locking Plate fixation, particularly for complex distal femur fractures, demonstrating better knee function, improved range of motion, and faster rehabilitation.

Authors

Publication Details

Journal
International Journal of Medical and All Body Health Research
Published
2025-01-01
DOI
https://doi.org/10.54660/ijmbhr.2025.6.3.200-207
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative Analysis of Functional Outcome of Distal Femur Fractures Treated with Locking Compression Plate Fixation and Non-Locking Plate Fixation

Tushar Jain, Rajesh Bhatia, RL Sahu, Harsh Pratap
International Journal of Medical and All Body Health Research
Bone fractures and treatments
article

A Comparative Analysis of Functional Outcome of Distal Femur Fractures Treated with Locking Compression Plate Fixation and Non-Locking Plate Fixation

Tushar Jain, Rajesh Bhatia, RL Sahu, Harsh Pratap
article en

Abstract

Background: Distal femur fractures represent a significant orthopedic challenge, requiring optimal fixation techniques to restore knee joint function and promote fracture healing. The choice between Locking Compression Plate (LCP) fixation and Non-Locking Plate fixation significantly impacts functional outcomes. Objective: To compare the functional outcomes of distal femur fractures treated with LCP fixation versus Non-Locking Plate fixation, focusing on knee function, fracture union time, range of motion, and post-operative recovery. Methods: A prospective observational study was conducted at Saraswathi Institute of Medical Sciences involving 60 adult patients (aged 18-70 years) with distal femur fractures. Patients were divided into two groups: 30 treated with LCP fixation and 30 with Non-Locking Plate fixation. Fractures were classified using Muller's classification system. Functional outcomes were assessed using the Hospital for Special Surgery (HSS) knee scoring system. Results: The LCP group demonstrated superior functional outcomes with 83.2% achieving excellent knee scores compared to 75.3% in the Non-Locking Plate group (p=0.004). Mean range of motion was significantly higher in the LCP group (111° ± 18.1) compared to the Non-Locking Plate group (92° ± 17.2) (p=0.0001). LCP fixation was preferred for complex fractures (C1, C2, C3 types), while Non-Locking Plates were more commonly used for simpler fractures. Conclusion: LCP fixation provides superior functional outcomes compared to Non-Locking Plate fixation, particularly for complex distal femur fractures, demonstrating better knee function, improved range of motion, and faster rehabilitation.

International Journal of Medical and All Body Health ResearchVol. 6(3)
Good health and well-being
Openalex Percentile: Top 71%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Comparative Analysis of Functional Outcome of Distal Femur Fractures Treated with Locking Compression Plate Fixation and Non-Locking Plate Fixation — Tushar Jain, Rajesh Bhatia, et al. · International Journal of Medical and All Body Health Research (2025) | TGRS Research Map | TGRS