Nonlinear relationship between signal and gas concentration in high-precision off-axis integrated cavity output spectroscopy

Abstract Off-axis integrated cavity output spectroscopy (OA-ICOS) is an extremely sensitive technique for measuring trace gas concentrations. Nevertheless, recent research has indicated that when the reflectivity of the mirrors forming the cavity is excessively high, it affects the linearity between the absorption signal and concentration. In this study, the causes and limitations of this phenomenon are discussed based on the Beer–Lambert law and the law of light propagation within the cavity. A new equation is derived to describe the nonlinear relationship between the integral area of absorption spectra and gas concentration. The absorption spectra of CO 2 and CH 4 , measured under different experimental conditions and concentrations, were fitted with Voigt functions to obtain parameters such as peak values and integral areas, which were used to verify the theoretical derivation process and results. The experimental results demonstrate that the relationship between the area of the measured absorption spectra and the gas concentration is consistent with the new formula, with an average fitting correlation coefficient of 0.9998. Meanwhile, the experimental results also demonstrate that the effective optical path length indeed decreases with increasing concentration. Furthermore, the cavity reflectances (99.99644% at 6242.6 cm −1 and 99.99833% at 6046.96 cm −1 ) derived from the fitting coefficient of the new concentration expression closely match the reflectances (99.99727% at 6242.6 cm −1 and 99.99868% at 6046.96 cm −1 ) obtained by applying the classical formula to the spectra of the lowest gas concentration. These experimental results validate the theoretical deduction process and expression. This research provides insights for the theoretical and practical advancements of OA-ICOS, which is significant for advancing high-precision trace gas detection technology.

Authors

Institutions

Publication Details

Journal
Chinese Physics B
Published
2025-08-12
DOI
https://doi.org/10.1088/1674-1056/adfa79
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonlinear relationship between signal and gas concentration in high-precision off-axis integrated cavity output spectroscopy

Yi Jiao, Biao Ye, Jingjing Wang, Xinxin Wei et al.
Chinese Physics B
Spectroscopy and Laser Applications
article

Nonlinear relationship between signal and gas concentration in high-precision off-axis integrated cavity output spectroscopy

Yi Jiao, Biao Ye, Jingjing Wang, Xinxin Wei, Xin Meng
article en

Abstract

Abstract Off-axis integrated cavity output spectroscopy (OA-ICOS) is an extremely sensitive technique for measuring trace gas concentrations. Nevertheless, recent research has indicated that when the reflectivity of the mirrors forming the cavity is excessively high, it affects the linearity between the absorption signal and concentration. In this study, the causes and limitations of this phenomenon are discussed based on the Beer–Lambert law and the law of light propagation within the cavity. A new equation is derived to describe the nonlinear relationship between the integral area of absorption spectra and gas concentration. The absorption spectra of CO 2 and CH 4 , measured under different experimental conditions and concentrations, were fitted with Voigt functions to obtain parameters such as peak values and integral areas, which were used to verify the theoretical derivation process and results. The experimental results demonstrate that the relationship between the area of the measured absorption spectra and the gas concentration is consistent with the new formula, with an average fitting correlation coefficient of 0.9998. Meanwhile, the experimental results also demonstrate that the effective optical path length indeed decreases with increasing concentration. Furthermore, the cavity reflectances (99.99644% at 6242.6 cm −1 and 99.99833% at 6046.96 cm −1 ) derived from the fitting coefficient of the new concentration expression closely match the reflectances (99.99727% at 6242.6 cm −1 and 99.99868% at 6046.96 cm −1 ) obtained by applying the classical formula to the spectra of the lowest gas concentration. These experimental results validate the theoretical deduction process and expression. This research provides insights for the theoretical and practical advancements of OA-ICOS, which is significant for advancing high-precision trace gas detection technology.

Chinese Physics BVol. 35(3)
Jiangsu Normal University (CN)
Peace, Justice and strong institutions
Openalex Percentile: Top 81%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nonlinear relationship between signal and gas concentration in high-precision off-axis integrated cavity output spectroscopy — Yi Jiao, Biao Ye, et al. · Chinese Physics B (2025) | TGRS Research Map | TGRS