Ultraviolet light disinfection of flexible endoscopes without working channels – a systematic review and assessment of medical and economical aspects

Abstract Introduction The objective of this report was to evaluate the disinfection process of flexible endoscopes without working channels using ultraviolet (UV) light, in comparison to the currently recommended reprocessing method, in a clinical setting. Method A comprehensive search of articles was conducted in November 2024 across Medline, Embase, CINAHL, and CENTRAL databases. Ongoing studies and Health Technology Assessment (HTA) reports were also searched. The selected studies were assessed by at least two independent authors, and inclusion decisions made by consensus. The studies underwent critical appraisal, and relevant data were extracted. Data on the level of disinfection were pooled in a meta-analysis using R software. The certainty of the evidence was evaluated using the GRADE approach. In collaboration with experienced hygiene nurses and a physician involved in the project, organizational issues related to implementation were addressed, and a health economic analysis was conducted. Result Manual pre-cleaning followed by ultraviolet (UV) light disinfection of flexible endoscopes without working channels may offer a slightly higher level of effectiveness compared to the currently employed reprocessing method using an endoscope washer-disinfector. An organizational review indicates that there are benefits to using UVC light, as the disinfection process is faster and requires fewer installations. The health economic analysis supports the use of UV-light disinfection due to lower investment and running costs. Discussion This health technology assessment can be used as a decision basis for a preferred desinfection process at units using flexible endoscopes without working channels.

Authors

Institutions

Publication Details

Journal
British journal of surgery
Published
2025-08-01
DOI
https://doi.org/10.1093/bjs/znaf149.132
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultraviolet light disinfection of flexible endoscopes without working channels – a systematic review and assessment of medical and economical aspects

Sofia Löfvendahl, Folke Johnsson, Linnea Huss, Anna Holmberg et al.
British journal of surgery
Medical Device Sterilization and Disinfection
article

Ultraviolet light disinfection of flexible endoscopes without working channels – a systematic review and assessment of medical and economical aspects

Sofia Löfvendahl, Folke Johnsson, Linnea Huss, Anna Holmberg, Eric Ahl, Anna Lunde, Helene Nilsson Lundahl, Ylva Sundin
article en

Abstract

Abstract Introduction The objective of this report was to evaluate the disinfection process of flexible endoscopes without working channels using ultraviolet (UV) light, in comparison to the currently recommended reprocessing method, in a clinical setting. Method A comprehensive search of articles was conducted in November 2024 across Medline, Embase, CINAHL, and CENTRAL databases. Ongoing studies and Health Technology Assessment (HTA) reports were also searched. The selected studies were assessed by at least two independent authors, and inclusion decisions made by consensus. The studies underwent critical appraisal, and relevant data were extracted. Data on the level of disinfection were pooled in a meta-analysis using R software. The certainty of the evidence was evaluated using the GRADE approach. In collaboration with experienced hygiene nurses and a physician involved in the project, organizational issues related to implementation were addressed, and a health economic analysis was conducted. Result Manual pre-cleaning followed by ultraviolet (UV) light disinfection of flexible endoscopes without working channels may offer a slightly higher level of effectiveness compared to the currently employed reprocessing method using an endoscope washer-disinfector. An organizational review indicates that there are benefits to using UVC light, as the disinfection process is faster and requires fewer installations. The health economic analysis supports the use of UV-light disinfection due to lower investment and running costs. Discussion This health technology assessment can be used as a decision basis for a preferred desinfection process at units using flexible endoscopes without working channels.

British journal of surgeryVol. 112(Supplement_11)
Skåne University Hospital (SE)
Openalex Percentile: Top 81%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.