Titanium Elastic Nailing System in Treatment of Fracture Shaft of Tibia in Children and Adolescents: A Prospective Observational Study

BACKGROUND Tibial shaft fractures are common pediatric injuries, often requiring surgical intervention when conservative management fails. The Titanium Elastic Nailing System (TENS) has gained popularity due to its minimally invasive nature, stable fixation, and ability to preserve growth plates. This study evaluates the functional and radiological outcomes of pediatric tibial shaft fractures treated with TENS in a resource-limited setting. METHODS A prospective observational study was conducted at the National Level Tertiary Care Trauma Center in Nepal, from February 2019 to January 2020. Forty-six patients aged 5–18 years with unstable tibial shaft fractures were treated with TENS. Functional outcomes were assessed using Flynn’s criteria, and radiological union was evaluated using the Radiographic Union Scale for Tibia (RUST). Statistical analysis was performed to identify factors influencing outcomes. RESULTS The mean age of participants was 9.89 ± 2.79 years, with 58.7% male. Most fractures were closed (93.5%) and located in the middle third of the tibia (69.6%). Excellent outcomes were achieved in 84.8% of cases, with a mean union time of 10.35 ± 2.25 weeks. Significant predictors of poor outcomes included limb length discrepancy (p = 0.007), angulation (p < 0.001), delayed union (p < 0.001), restricted knee range of motion (p = 0.019), and persistent pain (p = 0.001). CONCLUSION TENS is an effective treatment for pediatric tibial shaft fractures, offering excellent functional and radiological outcomes. Proper alignment, timely union, and early mobilization are critical for optimal recovery. Addressing complications such as angulation and persistent pain, particularly in resource-limited settings, is essential to maximize outcomes. KEYWORDS Titanium Elastic Nailing System (TENS), pediatric tibial fractures, Flynn’s criteria, radiological union, limb length discrepancy

Authors

Publication Details

Journal
Nepal Orthopaedic Association Journal
Published
2025-08-01
DOI
https://doi.org/10.59173/noaj20251102b
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Titanium Elastic Nailing System in Treatment of Fracture Shaft of Tibia in Children and Adolescents: A Prospective Observational Study

Ramesh Aryal
Nepal Orthopaedic Association Journal
Bone fractures and treatments
article

Titanium Elastic Nailing System in Treatment of Fracture Shaft of Tibia in Children and Adolescents: A Prospective Observational Study

Ramesh Aryal
article en

Abstract

BACKGROUND Tibial shaft fractures are common pediatric injuries, often requiring surgical intervention when conservative management fails. The Titanium Elastic Nailing System (TENS) has gained popularity due to its minimally invasive nature, stable fixation, and ability to preserve growth plates. This study evaluates the functional and radiological outcomes of pediatric tibial shaft fractures treated with TENS in a resource-limited setting. METHODS A prospective observational study was conducted at the National Level Tertiary Care Trauma Center in Nepal, from February 2019 to January 2020. Forty-six patients aged 5–18 years with unstable tibial shaft fractures were treated with TENS. Functional outcomes were assessed using Flynn’s criteria, and radiological union was evaluated using the Radiographic Union Scale for Tibia (RUST). Statistical analysis was performed to identify factors influencing outcomes. RESULTS The mean age of participants was 9.89 ± 2.79 years, with 58.7% male. Most fractures were closed (93.5%) and located in the middle third of the tibia (69.6%). Excellent outcomes were achieved in 84.8% of cases, with a mean union time of 10.35 ± 2.25 weeks. Significant predictors of poor outcomes included limb length discrepancy (p = 0.007), angulation (p < 0.001), delayed union (p < 0.001), restricted knee range of motion (p = 0.019), and persistent pain (p = 0.001). CONCLUSION TENS is an effective treatment for pediatric tibial shaft fractures, offering excellent functional and radiological outcomes. Proper alignment, timely union, and early mobilization are critical for optimal recovery. Addressing complications such as angulation and persistent pain, particularly in resource-limited settings, is essential to maximize outcomes. KEYWORDS Titanium Elastic Nailing System (TENS), pediatric tibial fractures, Flynn’s criteria, radiological union, limb length discrepancy

Nepal Orthopaedic Association Journal
Openalex Percentile: Top 71%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.