The Design of Main Electric Circuit for the Yebatan Hydropower Station

The Yebatan hydropower station consist of 6 hydraulic generators with total 2240 MW installed capacity. 4 sets of 510MW generators are connect with 4 main transformers. 2 sets of 200MW eco-unit generators and 2 main transformers are connected into joint units (for mutual backup). 4 large units and 2 eco-units are arranged in the same underground powerhouse. However their tailrace tunnels and outlets are arranged separately. The 500kV high voltage cables are arranged at both sides in an outgoing shaft with a height of 303m. The bottom and top of the shaft are connected by flat tunnels, and a traffic tunnel is set in the middle of the shaft. High slope anchor cable behind switch station is adopted to set up the output hanging point.

Authors

Institutions

Publication Details

Published
2025-05-17
DOI
https://doi.org/10.1109/icet64964.2025.11102885
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Design of Main Electric Circuit for the Yebatan Hydropower Station

Huang Kai, Ying Qin, Li Kai, Mao Zewei et al.
High-Voltage Power Transmission Systems
article

The Design of Main Electric Circuit for the Yebatan Hydropower Station

Huang Kai, Ying Qin, Li Kai, Mao Zewei, Pang Yuanjie, Du Peilin
article en

Abstract

The Yebatan hydropower station consist of 6 hydraulic generators with total 2240 MW installed capacity. 4 sets of 510MW generators are connect with 4 main transformers. 2 sets of 200MW eco-unit generators and 2 main transformers are connected into joint units (for mutual backup). 4 large units and 2 eco-units are arranged in the same underground powerhouse. However their tailrace tunnels and outlets are arranged separately. The 500kV high voltage cables are arranged at both sides in an outgoing shaft with a height of 303m. The bottom and top of the shaft are connected by flat tunnels, and a traffic tunnel is set in the middle of the shaft. High slope anchor cable behind switch station is adopted to set up the output hanging point.

China Power Engineering Consulting Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 81%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.