Machine Learning-Driven EMG-Based 3D Prosthetic Arm with 5 Degrees of Freedom

the study includes the designing, testing and controlling of prosthetic arm, which is flexible, wearable, non-invasive, efficient and cost-effective. It has 5 degrees of freedom and can perform six gestures. It was developed under 500 USD which is a low cost, has a mass of approximately 1 kg and was tested on ten subjects. The surface electromyogram (sEMG) signals were obtained from four MyoWare EMG sensors attached to amputee's forearm detecting electrical activity in four muscles: Brachialis, Palmaris longus, Flexor digitorum, and Extensor digitorum. Using raw sEMG signals, six time-domain features namely integrated signal, zero crossing, variance, root mean square, mean absolute value, and short time Fourier transform were calculated and considered for classification. The processed features were then fed into different three classifiers namely decision tree (DT), support vector machine (SVM), and artificial neural networks (ANN) for the purpose of training the classifiers. It was also deduced that root mean square and short time fourier transform as features and SVM as classifier performed relatively better with (p= 0.04) and accuracy 92.35 percent as compared to all other features and classifiers. In the offline mode the classification accuracy is 85.18,81.16 and 92.35 percent for ANN, DT and SVM classifiers respectively. Similarly, in the real mode, the least individual accuracy is 85 percent. To ensure that the results were accurate, all the classifiers and the vibrotactile feedback mechanism were put to the test. In the case of the vibrotactile force sensing feedback mechanism, statistical testing revealed a p-value of 0.04 and a correlation coefficient of 0.9985 between matching and target forces exerted by the fingers, disproving the null hypothesis and establishing an authentic connection.

Authors

Institutions

Publication Details

Published
2025-05-29
DOI
https://doi.org/10.1109/eit64391.2025.11103684
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine Learning-Driven EMG-Based 3D Prosthetic Arm with 5 Degrees of Freedom

Atika Qazi, Maryam Sherazi, Daniel S. Engstrøm, Syed Haider Ali Sherazi et al.
Muscle activation and electromyography studies
article

Machine Learning-Driven EMG-Based 3D Prosthetic Arm with 5 Degrees of Freedom

Atika Qazi, Maryam Sherazi, Daniel S. Engstrøm, Syed Haider Ali Sherazi, Fahad Qaseem Khawar
article en

Abstract

the study includes the designing, testing and controlling of prosthetic arm, which is flexible, wearable, non-invasive, efficient and cost-effective. It has 5 degrees of freedom and can perform six gestures. It was developed under 500 USD which is a low cost, has a mass of approximately 1 kg and was tested on ten subjects. The surface electromyogram (sEMG) signals were obtained from four MyoWare EMG sensors attached to amputee's forearm detecting electrical activity in four muscles: Brachialis, Palmaris longus, Flexor digitorum, and Extensor digitorum. Using raw sEMG signals, six time-domain features namely integrated signal, zero crossing, variance, root mean square, mean absolute value, and short time Fourier transform were calculated and considered for classification. The processed features were then fed into different three classifiers namely decision tree (DT), support vector machine (SVM), and artificial neural networks (ANN) for the purpose of training the classifiers. It was also deduced that root mean square and short time fourier transform as features and SVM as classifier performed relatively better with (p= 0.04) and accuracy 92.35 percent as compared to all other features and classifiers. In the offline mode the classification accuracy is 85.18,81.16 and 92.35 percent for ANN, DT and SVM classifiers respectively. Similarly, in the real mode, the least individual accuracy is 85 percent. To ensure that the results were accurate, all the classifiers and the vibrotactile feedback mechanism were put to the test. In the case of the vibrotactile force sensing feedback mechanism, statistical testing revealed a p-value of 0.04 and a correlation coefficient of 0.9985 between matching and target forces exerted by the fingers, disproving the null hypothesis and establishing an authentic connection.

Wayne State University (US), Lahore University of Management Sciences (PK), University of Health Sciences Lahore (PK), Danish Technological Institute (DK), Ghulam Ishaq Khan Institute of Engineering Sciences and Technology (PK), University of Veterinary and Animal Sciences (PK)
Gender equality
Openalex Percentile: Top 81%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.