Research on a New Type of Neutral Point Grounding Protection Device for Transformers

Traditional transformer neutral grounding protection device, using a combination of discharge gap and lightning arrester, discharge gap rod pole exists easy to trigger flashover along the surface, low corona voltage, with inaccurate parameters, poor arc extinguishing ability, overvoltage protection dead zone, easy to cause circuit breaker error operation and other defects. In this paper, for the above problems, a new transformer neutral grounding protection device is proposed, which adopts the combination device of logic control module, voltage transformer, current transformer, fast load switch and lightning arrester, and pre-set the closing and breaking voltage range of fast load switch by comparing the circuits, accurately restricts the protection range of fast load switch and lightning arrester, It effectively solves the problems of high failure rate, low sensitivity, poor accuracy and large dead zone of over-voltage protection existing in the current transformer neutral grounding protection device.

Authors

Institutions

Publication Details

Published
2025-05-17
DOI
https://doi.org/10.1109/icet64964.2025.11102887
Primary Topic
Engineering and Test Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on a New Type of Neutral Point Grounding Protection Device for Transformers

Peng Yu, Yuhong Chen, Yi He, Dan Yu et al.
Engineering and Test Systems
article

Research on a New Type of Neutral Point Grounding Protection Device for Transformers

Peng Yu, Yuhong Chen, Yi He, Dan Yu, Yun Peng, Ding Kuang
article en

Abstract

Traditional transformer neutral grounding protection device, using a combination of discharge gap and lightning arrester, discharge gap rod pole exists easy to trigger flashover along the surface, low corona voltage, with inaccurate parameters, poor arc extinguishing ability, overvoltage protection dead zone, easy to cause circuit breaker error operation and other defects. In this paper, for the above problems, a new transformer neutral grounding protection device is proposed, which adopts the combination device of logic control module, voltage transformer, current transformer, fast load switch and lightning arrester, and pre-set the closing and breaking voltage range of fast load switch by comparing the circuits, accurately restricts the protection range of fast load switch and lightning arrester, It effectively solves the problems of high failure rate, low sensitivity, poor accuracy and large dead zone of over-voltage protection existing in the current transformer neutral grounding protection device.

Chengdu Medical College (CN)
Openalex Percentile: Top 75%
Engineering and Test Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.