Transformer Winding Fault Diagnosis Method Based on Improved BP Neural Network

Aiming at the problem of insufficient samples of transformer winding faults in the field and the difficulty of direct online frequency response testing, we constructed an online monitoring platform based on station transformer winding injection. By simulating short-circuit and spacing change faults between pancakes, the amplitude-frequency response curve of the response current signal is acquired and plotted using a high-frequency response current signal acquisition device. Then, statistical features and image color features are extracted from the amplitude-frequency response curve. Based on the station transformer injection method, the five most important feature parameters are selected using the random forest feature selection method. Finally, the BP neural network classification algorithm is improved by combining the dung beetle algorithm in order to realize the accurate identification and diagnosis of winding fault types.

Authors

Institutions

Publication Details

Published
2025-05-17
DOI
https://doi.org/10.1109/icet64964.2025.11103377
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transformer Winding Fault Diagnosis Method Based on Improved BP Neural Network

Dexu Zou, Guochao Qian, Zhihu Hong, Shan Wang et al.
Power Transformer Diagnostics and Insulation
article

Transformer Winding Fault Diagnosis Method Based on Improved BP Neural Network

Dexu Zou, Guochao Qian, Zhihu Hong, Shan Wang, Hongbo Wang, Hongwen Liu, Jin Hu
article en

Abstract

Aiming at the problem of insufficient samples of transformer winding faults in the field and the difficulty of direct online frequency response testing, we constructed an online monitoring platform based on station transformer winding injection. By simulating short-circuit and spacing change faults between pancakes, the amplitude-frequency response curve of the response current signal is acquired and plotted using a high-frequency response current signal acquisition device. Then, statistical features and image color features are extracted from the amplitude-frequency response curve. Based on the station transformer injection method, the five most important feature parameters are selected using the random forest feature selection method. Finally, the BP neural network classification algorithm is improved by combining the dung beetle algorithm in order to realize the accurate identification and diagnosis of winding fault types.

Southwest Jiaotong University (CN), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 81%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transformer Winding Fault Diagnosis Method Based on Improved BP Neural Network — Dexu Zou, Guochao Qian, et al. · (2025) | TGRS Research Map | TGRS