Research on Voltage Equalization Characteristics of Ultra-High Voltage Ac 1000 Kv Substation Based on Twin Noise Reduction Technology for Digital Model

In Cole-Cole diagram, first considers conductivity polarization, and the second one does not consider conductivity polarization. In Cole-Cole without considering conductivity, the partial shapes of the two arcs can be seen. In terms of fitting effect, the model that combines the three HN equations fits the experimental data very well with small errors. When runway type voltage equalizing ring is configured and carried to middle position between the second and third insulators, the distributed voltage of the insulator on wire side drops to about 26 kV, with maximum value of 27.5 kV, and maximum field strength appears at the head of insulator. From this, it can be seen that configuring voltage equalization ring significantly improve the distribution voltage of insulators. It was found that Arrhenius formula was no longer applicable to fitting of epoxy resin samples. Two segments were selected to fit the experimental data separately.

Authors

Institutions

Publication Details

Published
2025-05-17
DOI
https://doi.org/10.1109/icet64964.2025.11103094
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Voltage Equalization Characteristics of Ultra-High Voltage Ac 1000 Kv Substation Based on Twin Noise Reduction Technology for Digital Model

Hao Feng, Shiling Zhang, Pengbo Wang, Qiang Xiao
High-Voltage Power Transmission Systems
article

Research on Voltage Equalization Characteristics of Ultra-High Voltage Ac 1000 Kv Substation Based on Twin Noise Reduction Technology for Digital Model

Hao Feng, Shiling Zhang, Pengbo Wang, Qiang Xiao
article en

Abstract

In Cole-Cole diagram, first considers conductivity polarization, and the second one does not consider conductivity polarization. In Cole-Cole without considering conductivity, the partial shapes of the two arcs can be seen. In terms of fitting effect, the model that combines the three HN equations fits the experimental data very well with small errors. When runway type voltage equalizing ring is configured and carried to middle position between the second and third insulators, the distributed voltage of the insulator on wire side drops to about 26 kV, with maximum value of 27.5 kV, and maximum field strength appears at the head of insulator. From this, it can be seen that configuring voltage equalization ring significantly improve the distribution voltage of insulators. It was found that Arrhenius formula was no longer applicable to fitting of epoxy resin samples. Two segments were selected to fit the experimental data separately.

Chongqing University (CN), Shanghai Electric (China) (CN), Economic Research Institute (BG)
Affordable and clean energy
Openalex Percentile: Top 81%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.