Optimization Practice of Insulation Structure of Converter Transformer Based on Artificial Intelligence 3D Configuration and Data Processing

Due to high current of 6300A, the bushing adopts a double conduit direct current carrying structure. The current carrying conduit refers to the bushing 60533 of the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$170 \text{kV / 6000} \mathrm{A}$</tex> oil paper capacitor transformer supplied, which uses a diameter of the 105 copper tube. The relative error between the root mean square value of voltage meter reading and average value meter reading is much greater than 3 %. The method is to divide the capacitor core into three parts, uniformly insert the 1-4 layers of auxiliary plates (small plates) with the length of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{3 0 0 - 5 0 0 m m}$</tex> into the insulation layer between main plates (large plates). it can be seen temperature has significant impact on polarity of interface charges. When experimental temperature is 40° C, charge peak appears at interface 1 and a positive charge peak appears at the interface 2, and the charge amount increases with the time. When experimental temperature was at 80° C, the positive charge peak appeared at interface 1 and the negative charge peak appeared at interface 2. The charge amount reached its maximum value at 5000s, and then showed decreasing trend.

Authors

Institutions

Publication Details

Published
2025-05-17
DOI
https://doi.org/10.1109/icet64964.2025.11103322
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization Practice of Insulation Structure of Converter Transformer Based on Artificial Intelligence 3D Configuration and Data Processing

Xiangcheng Li, Shiling Zhang, Haoyu Wang, Pengbo Wang
High voltage insulation and dielectric phenomena
article

Optimization Practice of Insulation Structure of Converter Transformer Based on Artificial Intelligence 3D Configuration and Data Processing

Xiangcheng Li, Shiling Zhang, Haoyu Wang, Pengbo Wang
article en

Abstract

Due to high current of 6300A, the bushing adopts a double conduit direct current carrying structure. The current carrying conduit refers to the bushing 60533 of the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$170 \text{kV / 6000} \mathrm{A}$</tex> oil paper capacitor transformer supplied, which uses a diameter of the 105 copper tube. The relative error between the root mean square value of voltage meter reading and average value meter reading is much greater than 3 %. The method is to divide the capacitor core into three parts, uniformly insert the 1-4 layers of auxiliary plates (small plates) with the length of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{3 0 0 - 5 0 0 m m}$</tex> into the insulation layer between main plates (large plates). it can be seen temperature has significant impact on polarity of interface charges. When experimental temperature is 40° C, charge peak appears at interface 1 and a positive charge peak appears at the interface 2, and the charge amount increases with the time. When experimental temperature was at 80° C, the positive charge peak appeared at interface 1 and the negative charge peak appeared at interface 2. The charge amount reached its maximum value at 5000s, and then showed decreasing trend.

Chongqing University (CN), Economic Research Institute (BG)
Affordable and clean energy
Openalex Percentile: Top 85%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.