Testing and Noise Assessment of Two Types of Bridge Expansion Joints: Case Study

Expansion joints mounted on the edges of bridges can cause excessive noise and environmental nuisance. Currently, there are no standardized European methods for assessing the noise of these devices. This article presents the results of investigations of two expansion joint devices: a modular one used for small displacements and a finger one used for large displacements. The method proposed in the Austrian standard was used to evaluate the acoustic effects. The exposure levels of the sound were compared after analyzing 100 reliable car passes through each device. Acoustic signals were recorded and analyzed at three points. In the case of the modular device, the average exposure sound level above the device was 2.6 dB higher than the noise above one outside the device. For a finger device, the difference was 1.2 dB. The latter device can be considered “low-noise”. The amplitude–frequency characteristics of the recorded phenomena were also analyzed to show which frequencies are responsible for excessive noise. The dependence of sound emissions on the speed of cars was also determined. The conducted research has shown that the adopted method can be successfully used for the acoustic evaluation of expansion joint devices.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-08-12
DOI
https://doi.org/10.3390/app15168901
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Testing and Noise Assessment of Two Types of Bridge Expansion Joints: Case Study

L. Janas
Applied Sciences
Structural Health Monitoring Techniques
article

Testing and Noise Assessment of Two Types of Bridge Expansion Joints: Case Study

L. Janas
article en

Abstract

Expansion joints mounted on the edges of bridges can cause excessive noise and environmental nuisance. Currently, there are no standardized European methods for assessing the noise of these devices. This article presents the results of investigations of two expansion joint devices: a modular one used for small displacements and a finger one used for large displacements. The method proposed in the Austrian standard was used to evaluate the acoustic effects. The exposure levels of the sound were compared after analyzing 100 reliable car passes through each device. Acoustic signals were recorded and analyzed at three points. In the case of the modular device, the average exposure sound level above the device was 2.6 dB higher than the noise above one outside the device. For a finger device, the difference was 1.2 dB. The latter device can be considered “low-noise”. The amplitude–frequency characteristics of the recorded phenomena were also analyzed to show which frequencies are responsible for excessive noise. The dependence of sound emissions on the speed of cars was also determined. The conducted research has shown that the adopted method can be successfully used for the acoustic evaluation of expansion joint devices.

Applied SciencesVol. 15(16)
Rzeszów University of Technology (PL)
Narodowe Centrum Badań i Rozwoju
Openalex Percentile: Top 78%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Testing and Noise Assessment of Two Types of Bridge Expansion Joints: Case Study — L. Janas · Applied Sciences (2025) | TGRS Research Map | TGRS