Peripheral Intravenous Catheter Failure in Hospitalized Patients: Bridging the Gap between Microbiological Data and Clinical Indicators and possible relevance to therapeutic targets

The peripheral intravenous catheter (PIC) is most commonly used invasive technology among inpatients, frequently associated with hospital procedures worldwide. However, PIC insertion presents multiple challenges, particularly the risk for catheter-related infections (CRI), which remain a preventable concern. Additionally, catheter failure imposes financial burdens on healthcare system. The goal is to establish a baseline for peripheral intravenous catheter failure (PICF) rates and incidences as part of a larger quality improvement. A total of 450 hospitalized patients diagnosed with PICF were included in the research, with 1263 catheters examined. PICs were placed in patients across hospital wards, ICUs, emergency departments and operating rooms. Among 700 cultured catheter tips, 302 were identified as PICF. The Hospital Length of Stay (HLOS) rate density-adjusted incidence for PICF revealed 35 out of 700 tips with positive isolates. No patients were diagnosed with CRI type three, where microbial development was concordant in tip and blood cultures. However, 12 out of 35 patients had CRI-compatible local signs and symptoms had positive cultures, while 11 exhibited symptoms within 48 hours after the removal of the catheter. The research shows that PICs caused unintended removal, which increases their significance for patient safety, illness and death. Numerous positive tip cultures were detected in the absence of any clinical indications. To emphasize that avoid CRI, it is crucial to eliminate needless PICs.

Authors

Institutions

Publication Details

Journal
Health Leadership and Quality of Life
Published
2025-08-04
DOI
https://doi.org/10.56294/hl2025326
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Peripheral Intravenous Catheter Failure in Hospitalized Patients: Bridging the Gap between Microbiological Data and Clinical Indicators and possible relevance to therapeutic targets

Geetika M. Patel, Baijayantimala Mohanty, Rahul Patil, Mithhil Arora et al.
Health Leadership and Quality of Life
Central Venous Catheters and Hemodialysis
article

Peripheral Intravenous Catheter Failure in Hospitalized Patients: Bridging the Gap between Microbiological Data and Clinical Indicators and possible relevance to therapeutic targets

Geetika M. Patel, Baijayantimala Mohanty, Rahul Patil, Mithhil Arora, Akhilesh Kalia, Bodireddy Vamalatha
article en

Abstract

The peripheral intravenous catheter (PIC) is most commonly used invasive technology among inpatients, frequently associated with hospital procedures worldwide. However, PIC insertion presents multiple challenges, particularly the risk for catheter-related infections (CRI), which remain a preventable concern. Additionally, catheter failure imposes financial burdens on healthcare system. The goal is to establish a baseline for peripheral intravenous catheter failure (PICF) rates and incidences as part of a larger quality improvement. A total of 450 hospitalized patients diagnosed with PICF were included in the research, with 1263 catheters examined. PICs were placed in patients across hospital wards, ICUs, emergency departments and operating rooms. Among 700 cultured catheter tips, 302 were identified as PICF. The Hospital Length of Stay (HLOS) rate density-adjusted incidence for PICF revealed 35 out of 700 tips with positive isolates. No patients were diagnosed with CRI type three, where microbial development was concordant in tip and blood cultures. However, 12 out of 35 patients had CRI-compatible local signs and symptoms had positive cultures, while 11 exhibited symptoms within 48 hours after the removal of the catheter. The research shows that PICs caused unintended removal, which increases their significance for patient safety, illness and death. Numerous positive tip cultures were detected in the absence of any clinical indications. To emphasize that avoid CRI, it is crucial to eliminate needless PICs.

Health Leadership and Quality of LifeVol. 4
Siksha O Anusandhan University (IN), Krishna Institute of Medical Sciences (IN), Parul University (IN), Advanced Numerical Research and Analysis Group (IN), Institute of Medical Sciences and Sum Hospital (IN), Chitkara University (IN)
Openalex Percentile: Top 68%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.