Linear Measurement of Corneal Density in Anterior Segment Spectral Optical Coherence Tomography (LM-SD-OCT)

Purpose: assess the accuracy of linear corneal density measurements obtained using spectral domain optical coherence tomography (OCT) in various images of normal corneas with the Image J program. Methods: Descriptive, cross-sectional, and observational study. Corneal images were captured using OCT Heidelberg Engineering with an anterior segment lens to calculate the average density of each layer in healthy corneas. We included subjects without corneal pathologies or surgeries and categorized them based on their age: 30 to 50 years, 51 to 70 years, and older than 70 years. The program image J of the NIH was used to calibrate the OCT image at a standardized value of 200 µm. Densities were obtained for the central cornea using high-resolution 8-bit images with 256 gray levels. Results: Spectral corneal OCT images of 140 eyes (170 patients) were analyzed, comprising 90 males and 80 females. The average gray value density for each corneal layer was determined, as follows: Te ar layer (238.25 ± 17.49), epithelium interface (91.55 ± 17), basal membrane and Bowman’s membrane (167.76 ± 16.19), anterior stroma (152.06 ± 9.09), posterior stroma (130.24 ± 8.32), and Descemet membrane (149.21 ± 7.80). Notably, optical densities significantly varied across different age groups and corneal layers (p Conclusions: The linear corneal layer densities obtained using the linear mode of spectral domain optical coherence tomography (SD-OCT) with Image J were a fast and practical method to complement the subjective descriptions of spectral anterior segment OCT images. These densities can then be compared across various pathologies.

Authors

Publication Details

Journal
Open Journal of Ophthalmology
Published
2025-01-01
DOI
https://doi.org/10.4236/ojoph.2025.153016
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Linear Measurement of Corneal Density in Anterior Segment Spectral Optical Coherence Tomography (LM-SD-OCT)

Jonathan Quevedo-Martínez, Luis R. Alvarez-Fernández, Oscar Fernández-Vizcaya
Open Journal of Ophthalmology
Corneal surgery and disorders
article

Linear Measurement of Corneal Density in Anterior Segment Spectral Optical Coherence Tomography (LM-SD-OCT)

Jonathan Quevedo-Martínez, Luis R. Alvarez-Fernández, Oscar Fernández-Vizcaya
article en

Abstract

Purpose: assess the accuracy of linear corneal density measurements obtained using spectral domain optical coherence tomography (OCT) in various images of normal corneas with the Image J program. Methods: Descriptive, cross-sectional, and observational study. Corneal images were captured using OCT Heidelberg Engineering with an anterior segment lens to calculate the average density of each layer in healthy corneas. We included subjects without corneal pathologies or surgeries and categorized them based on their age: 30 to 50 years, 51 to 70 years, and older than 70 years. The program image J of the NIH was used to calibrate the OCT image at a standardized value of 200 µm. Densities were obtained for the central cornea using high-resolution 8-bit images with 256 gray levels. Results: Spectral corneal OCT images of 140 eyes (170 patients) were analyzed, comprising 90 males and 80 females. The average gray value density for each corneal layer was determined, as follows: Te ar layer (238.25 ± 17.49), epithelium interface (91.55 ± 17), basal membrane and Bowman’s membrane (167.76 ± 16.19), anterior stroma (152.06 ± 9.09), posterior stroma (130.24 ± 8.32), and Descemet membrane (149.21 ± 7.80). Notably, optical densities significantly varied across different age groups and corneal layers (p Conclusions: The linear corneal layer densities obtained using the linear mode of spectral domain optical coherence tomography (SD-OCT) with Image J were a fast and practical method to complement the subjective descriptions of spectral anterior segment OCT images. These densities can then be compared across various pathologies.

Open Journal of OphthalmologyVol. 15(03)
Openalex Percentile: Top 71%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.