Effect of Layer Thickness on Conversion Degree and Microhardness of Bulk-Fill Composites

Background: This study aimed to evaluate the effect of layer thickness on the conversion degree and microhardness of low- and high-viscosity bulk-fill composite resins. Methods: Six different bulk-fill composite resins, SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (Voco), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), and Filtek Bulk Fill Flowable (3M ESPE) were tested. Disc-shaped samples (7 mm diameter, 2 and 4 mm thickness, n=4 per group) were prepared and polymerized using an LED (Light-Emitting Diode) curing unit (Elipar S10, 3M ESPE). After 24 hours at 37°C, the degree of conversion was analyzed using Fourier Transform Infrared Spectroscopy (FTIR)- Attenuated Total Reflectance (ATR) (Perkin Elmer Spectrum Two), and microhardness was measured using a Knoop hardness tester (Buehler MMT-3 Digital Microhardness Tester). Data were analyzed using Shapiro-Wilk, ANOVA, Tukey’s HSD, and Pearson correlation with SPSS 26.0V (IBM SPSS Corp.; Armonk, NY, USA). Results: No significant difference in bottom/top surface hardness ratio was observed in 2 mm samples (P > .05). However, at 4 mm, a statistically significant difference was found among the composite groups (P= .003). SDR had the highest hardness ratio (0.87 ± 0.04), while Beautifil Bulk Restorative (BBR) had the lowest (0.68 ± 0.08). The highest degree of conversion at both thicknesses was in SDR (65.13 ± 2.00 at 2 mm, 62.90 ± 2.30 at 4 mm), whereas X-tra Fil had the lowest (41.25 ± 13.57 at 2 mm, 39.25 ± 6.75 at 4 mm). In BBR, conversion at 2 mm was significantly higher than at 4 mm (P=.004). Cite this article as: Kütük Ömeroğlu M, Ertaş E. Effect of layer thickness on conversion degree and microhardness of bulk-fill composites. Essent Dent. 2025; 4, 0024, doi: 10.5152/EssentDent.2025.25024.

Authors

Institutions

Publication Details

Journal
Essentials of Dentistry
Published
2025-08-11
DOI
https://doi.org/10.5152/essentdent.2025.25024
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Layer Thickness on Conversion Degree and Microhardness of Bulk-Fill Composites

Merve Kütük Ömeroğlu, Doç. Dr. Ertan Ertaş
5 links
Essentials of Dentistry
Dental materials and restorations
article

Effect of Layer Thickness on Conversion Degree and Microhardness of Bulk-Fill Composites

Merve Kütük Ömeroğlu, Doç. Dr. Ertan Ertaş
article en

Abstract

Background: This study aimed to evaluate the effect of layer thickness on the conversion degree and microhardness of low- and high-viscosity bulk-fill composite resins. Methods: Six different bulk-fill composite resins, SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (Voco), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), and Filtek Bulk Fill Flowable (3M ESPE) were tested. Disc-shaped samples (7 mm diameter, 2 and 4 mm thickness, n=4 per group) were prepared and polymerized using an LED (Light-Emitting Diode) curing unit (Elipar S10, 3M ESPE). After 24 hours at 37°C, the degree of conversion was analyzed using Fourier Transform Infrared Spectroscopy (FTIR)- Attenuated Total Reflectance (ATR) (Perkin Elmer Spectrum Two), and microhardness was measured using a Knoop hardness tester (Buehler MMT-3 Digital Microhardness Tester). Data were analyzed using Shapiro-Wilk, ANOVA, Tukey’s HSD, and Pearson correlation with SPSS 26.0V (IBM SPSS Corp.; Armonk, NY, USA). Results: No significant difference in bottom/top surface hardness ratio was observed in 2 mm samples (P > .05). However, at 4 mm, a statistically significant difference was found among the composite groups (P= .003). SDR had the highest hardness ratio (0.87 ± 0.04), while Beautifil Bulk Restorative (BBR) had the lowest (0.68 ± 0.08). The highest degree of conversion at both thicknesses was in SDR (65.13 ± 2.00 at 2 mm, 62.90 ± 2.30 at 4 mm), whereas X-tra Fil had the lowest (41.25 ± 13.57 at 2 mm, 39.25 ± 6.75 at 4 mm). In BBR, conversion at 2 mm was significantly higher than at 4 mm (P=.004). Cite this article as: Kütük Ömeroğlu M, Ertaş E. Effect of layer thickness on conversion degree and microhardness of bulk-fill composites. Essent Dent. 2025; 4, 0024, doi: 10.5152/EssentDent.2025.25024.

Essentials of DentistryVol. 4(1)
Ondokuz Mayıs University (TR), Okan University (TR)
Openalex Percentile: Top 78%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Layer Thickness on Conversion Degree and Microhardness of Bulk-Fill Composites — Merve Kütük Ömeroğlu, Doç. Dr. Ertan Ertaş · Essentials of Dentistry (2025) | TGRS Research Map | TGRS