Neutron absorption correction and mean path length calculations for multiple samples with arbitrary shapes: application to highly absorbing samples on the Multi-Axis Crystal Spectrometer at NIST

Recent advancements in cold neutron instrumentation, designed to achieve the energy resolution necessary for studying strongly correlated materials, have driven the need for sophisticated modeling of neutron spectroscopy data from highly neutron-absorbing materials. These absorption effects are often highly dependent on both angular orientation and wavelength. To address this, the finite-volume algorithm for absorption correction developed by Wuensch & Prewitt [ Z. Kristallogr. (1965), 122 , 24–59] is examined in this paper in the context of cold neutron spectroscopy. This algorithm is based on the numerical integration of the transmission function, where three-dimensional quadratic surfaces define the sample boundaries. The algorithm can also determine the mean path length required for second-extinction calculations. We apply this method to neutron inelastic scattering measurements of an irregularly shaped CeRhIn 5 single crystal using the Multi-Axis Crystal Spectrometer at NIST. The algorithm has been expanded to correct for the absorption of multiple coaligned samples. We show that this procedure can account for the angle-dependent absorption, and the technique can be used to correct the data and plan experiments.

Authors

Institutions

Publication Details

Journal
Journal of Applied Crystallography
Published
2025-08-08
DOI
https://doi.org/10.1107/s1600576725006338
Primary Topic
Rare-earth and actinide compounds
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Neutron absorption correction and mean path length calculations for multiple samples with arbitrary shapes: application to highly absorbing samples on the Multi-Axis Crystal Spectrometer at NIST

J. A. Rodriguez‐Rivera, Chris Stock
Journal of Applied Crystallography
Rare-earth and actinide compounds
article

Neutron absorption correction and mean path length calculations for multiple samples with arbitrary shapes: application to highly absorbing samples on the Multi-Axis Crystal Spectrometer at NIST

J. A. Rodriguez‐Rivera, Chris Stock
article en

Abstract

Recent advancements in cold neutron instrumentation, designed to achieve the energy resolution necessary for studying strongly correlated materials, have driven the need for sophisticated modeling of neutron spectroscopy data from highly neutron-absorbing materials. These absorption effects are often highly dependent on both angular orientation and wavelength. To address this, the finite-volume algorithm for absorption correction developed by Wuensch & Prewitt [ Z. Kristallogr. (1965), 122 , 24–59] is examined in this paper in the context of cold neutron spectroscopy. This algorithm is based on the numerical integration of the transmission function, where three-dimensional quadratic surfaces define the sample boundaries. The algorithm can also determine the mean path length required for second-extinction calculations. We apply this method to neutron inelastic scattering measurements of an irregularly shaped CeRhIn 5 single crystal using the Multi-Axis Crystal Spectrometer at NIST. The algorithm has been expanded to correct for the absorption of multiple coaligned samples. We show that this procedure can account for the angle-dependent absorption, and the technique can be used to correct the data and plan experiments.

Journal of Applied CrystallographyVol. 58(5)
National Institute of Standards and Technology (US), NIST Center for Neutron Research (US), University of Maryland, College Park (US), University of Edinburgh (GB)
National Science Foundation
Openalex Percentile: Top 87%
Rare-earth and actinide compounds
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Neutron absorption correction and mean path length calculations for multiple samples with arbitrary shapes: application to highly absorbing samples on the Multi-Axis Crystal Spectrometer at NIST — J. A. Rodriguez‐Rivera, Chris Stock · Journal of Applied Crystallography (2025) | TGRS Research Map | TGRS