Rationales and Expectations with Upcoming New Line Surge Arrester (LSA) Standard IEC/IEEE 60099-11

Line Surge Arresters (LSAs) play a critical role in enhancing the reliability of overhead power lines by mitigating lightning-induced faults. Despite their widespread adoption worldwide, the standardization of LSAs remains inconsistent, particularly for Non-Gapped Line Arresters (NGLAs), which currently lack a dedicated testing framework tailored to their unique mechanical and electrical stress conditions. The upcoming IEC/IEEE 60099-11 standard aims to address these long-standing gaps by introducing a unified classification system, enhanced testing protocols, and improved performance requirements for both Externally Gapped Line Arresters (EGLAs) and NGLAs. This paper presents the rationale and key expectations for the new LSA standard, highlighting challenges associated with current LSA applications, including failure rates, inadequate mechanical testing, and inconsistencies in existing IEC and IEEE standards. A critical advancement in IEC/IEEE 60099-11 is the adoption of a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2 / 20 \mu$</tex> s waveshape for LSA classification, aligning with field experience and system studies on lightning performance. Additionally, the standard will establish new mechanical test requirements, including vibration, bending moment, and torsional withstand tests, to ensure the long-term reliability of LSAs under harsh operational conditions. By harmonizing IEC and IEEE requirements, IEC/IEEE 60099-11 will provide a comprehensive and standardized framework for evaluating and deploying LSAs, improving reliability and operational efficiency for power utilities worldwide. The paper underscores the importance of collaborative efforts among standardization bodies, manufacturers, and utilities in successfully implementing the new standard and advancing surge protection technology for overhead transmission and distribution networks.

Authors

Institutions

Publication Details

Published
2025-06-17
DOI
https://doi.org/10.1109/apl65034.2025.11108822
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rationales and Expectations with Upcoming New Line Surge Arrester (LSA) Standard IEC/IEEE 60099-11

Florent Giraudet
1 citations
Power Systems Fault Detection
1.21
article

Rationales and Expectations with Upcoming New Line Surge Arrester (LSA) Standard IEC/IEEE 60099-11

Florent Giraudet
article en
1 citations

Abstract

Line Surge Arresters (LSAs) play a critical role in enhancing the reliability of overhead power lines by mitigating lightning-induced faults. Despite their widespread adoption worldwide, the standardization of LSAs remains inconsistent, particularly for Non-Gapped Line Arresters (NGLAs), which currently lack a dedicated testing framework tailored to their unique mechanical and electrical stress conditions. The upcoming IEC/IEEE 60099-11 standard aims to address these long-standing gaps by introducing a unified classification system, enhanced testing protocols, and improved performance requirements for both Externally Gapped Line Arresters (EGLAs) and NGLAs. This paper presents the rationale and key expectations for the new LSA standard, highlighting challenges associated with current LSA applications, including failure rates, inadequate mechanical testing, and inconsistencies in existing IEC and IEEE standards. A critical advancement in IEC/IEEE 60099-11 is the adoption of a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2 / 20 \mu$</tex> s waveshape for LSA classification, aligning with field experience and system studies on lightning performance. Additionally, the standard will establish new mechanical test requirements, including vibration, bending moment, and torsional withstand tests, to ensure the long-term reliability of LSAs under harsh operational conditions. By harmonizing IEC and IEEE requirements, IEC/IEEE 60099-11 will provide a comprehensive and standardized framework for evaluating and deploying LSAs, improving reliability and operational efficiency for power utilities worldwide. The paper underscores the importance of collaborative efforts among standardization bodies, manufacturers, and utilities in successfully implementing the new standard and advancing surge protection technology for overhead transmission and distribution networks.

Oldham Council (GB)
Peace, Justice and strong institutions
Openalex Percentile: Top 18%
Power Systems Fault Detection
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rationales and Expectations with Upcoming New Line Surge Arrester (LSA) Standard IEC/IEEE 60099-11 — Florent Giraudet · (2025) | TGRS Research Map | TGRS