Flexible DC Grid Protection Scheme Based on Fitting Slope Magnitude

In view of the current problems of insufficient ability to withstand high resistance in the single-terminal protection of multi-terminal flexible DC grids, a flexible DC grid protection scheme based on the fitting slope is proposed. First, the expression of the current change rate during faults inside and outside the zone is theoretically derived. And it is found that there are obvious differences in the magnitude and steepness of the current during faults inside and outside the zone. Then a protection scheme is proposed based on this difference. The slope of the fitted current is used to identify faults inside and outside the zone. In view of the limitation that the fitted current may malfunction under high resistance conditions, it is proposed to use the fitted power to construct a fitted power assist criterion. Finally, a four-terminal flexible DC grid model is built to verify the protection scheme. The simulation results show that the proposed protection method can accurately identify faults and fault poles inside and outside the zone, and still has good sensitivity under high-resistance faults.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3598050
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible DC Grid Protection Scheme Based on Fitting Slope Magnitude

Minghui Hu, Shufeng Fan, Bin Zhou, Huanwen Wang et al.
IEEE Access
HVDC Systems and Fault Protection
article

Flexible DC Grid Protection Scheme Based on Fitting Slope Magnitude

Minghui Hu, Shufeng Fan, Bin Zhou, Huanwen Wang, Jingwei Liu, Min Zhang
article en

Abstract

In view of the current problems of insufficient ability to withstand high resistance in the single-terminal protection of multi-terminal flexible DC grids, a flexible DC grid protection scheme based on the fitting slope is proposed. First, the expression of the current change rate during faults inside and outside the zone is theoretically derived. And it is found that there are obvious differences in the magnitude and steepness of the current during faults inside and outside the zone. Then a protection scheme is proposed based on this difference. The slope of the fitted current is used to identify faults inside and outside the zone. In view of the limitation that the fitted current may malfunction under high resistance conditions, it is proposed to use the fitted power to construct a fitted power assist criterion. Finally, a four-terminal flexible DC grid model is built to verify the protection scheme. The simulation results show that the proposed protection method can accurately identify faults and fault poles inside and outside the zone, and still has good sensitivity under high-resistance faults.

IEEE AccessVol. 13
Zhumadian Central Hospital (CN), Gree (China) (CN), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Sustainable cities and communities
Openalex Percentile: Top 81%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Flexible DC Grid Protection Scheme Based on Fitting Slope Magnitude — Minghui Hu, Shufeng Fan, et al. · IEEE Access (2025) | TGRS Research Map | TGRS