Online Monitoring the Arc Contacts Erosion of HVCBs Based on Radiation Signals

Arc contacts are the key components that affect the lifespan of high-voltage circuit breakers (HVCBs). During the operation process, the arc contacts are continuously eroded and suffer mass loss. The direct impact of arc contacts degradation is the delay of the contact point. However, the present online monitoring methods cannot directly observe the condition of arc contacts. This study proposed three methods for online monitoring the contact point of HVCBs. By monitoring arc-excited radiation signals and analyzing their correlation with HVCB operations, we reveal that the contact and separation of arc contacts can be distinguished by radiation signals and support contact point measurement. Tests conducted on four different breakers show that the average measurement error is less than 1 mm and the average error percentage is less than 6%. The combined application of the proposed method further improves the monitoring performance. Proposed solution is applicable to all types of HVCBs, not invading into the circuit breaker (CB), not requiring multiple premeasurements or establishing a dataset, and applicable for online monitoring, which has good application potential.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3598400
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Online Monitoring the Arc Contacts Erosion of HVCBs Based on Radiation Signals

Aijun Yang, Jifeng Chu, Chenhui Li, Mingzhe Rong et al.
IEEE Transactions on Instrumentation and Measurement
Electrical Fault Detection and Protection
article

Online Monitoring the Arc Contacts Erosion of HVCBs Based on Radiation Signals

Aijun Yang, Jifeng Chu, Chenhui Li, Mingzhe Rong, Xiaohua Wang, Jingyu Yuan, X. Long
article en

Abstract

Arc contacts are the key components that affect the lifespan of high-voltage circuit breakers (HVCBs). During the operation process, the arc contacts are continuously eroded and suffer mass loss. The direct impact of arc contacts degradation is the delay of the contact point. However, the present online monitoring methods cannot directly observe the condition of arc contacts. This study proposed three methods for online monitoring the contact point of HVCBs. By monitoring arc-excited radiation signals and analyzing their correlation with HVCB operations, we reveal that the contact and separation of arc contacts can be distinguished by radiation signals and support contact point measurement. Tests conducted on four different breakers show that the average measurement error is less than 1 mm and the average error percentage is less than 6%. The combined application of the proposed method further improves the monitoring performance. Proposed solution is applicable to all types of HVCBs, not invading into the circuit breaker (CB), not requiring multiple premeasurements or establishing a dataset, and applicable for online monitoring, which has good application potential.

IEEE Transactions on Instrumentation and MeasurementVol. 74
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Climate action
Openalex Percentile: Top 81%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.