Elucidating the Reactivity of Reflectance-Based Core-Body Photoplethysmogram to Posture and Respiratory Changes

At-home cardiovascular monitoring has become widespread with the commercialization of the photoplethysmogram (PPG) in wearable devices. A tremendous opportunity for comprehensive monitoring of chronotropic, inotropic, and vascular characteristics of the cardiovascular system can be unlocked if PPG data are combined with signals of other modalities at the core body. However, little is known about the quality of core-body PPG or its reactivity to environmental conditions. To elucidate core-body PPG signals, we compared the reactivity and quality of sternum and back PPG signals to finger-based PPG in 24 healthy participants during a protocol with posture and breathing changes. We found that signal quality of core-body PPG was affected by body location, wavelength, LED/photodiode configuration, posture, and breathing pattern. Notably, reflectance-mode red-wavelength core-body quality was less than that of transmittance-mode finger red-wavelength PPG (p<0.05). However, green-wavelength core-body PPG quality was comparable (p>0.05, sternum) or significantly greater (p<0.001, back). We also found that PPG amplitude reactivity for core-body signals was in accordance with that of the finger (p>0.05 or p<0.05, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>=</mml:mo> <mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo></mml:mrow> </mml:math> ) for posture changes but opposite (p<0.05, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>≠</mml:mo> <mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo></mml:mrow> </mml:math> ) or significantly blunted (p<0.05, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>=</mml:mo> <mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>,</mml:mo> <mml:mi>abs</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo><</mml:mo> <mml:mi>abs</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo></mml:mrow> </mml:math> ) during deep and resistive breathing. We, thus, demonstrate the importance of studying the reactivity of vasculature at different sensor locations as their reactivity to various provocations is heterogeneous. Our findings can be used to develop improved hardware for sensing core-body PPG and algorithms for interpreting the signals acquired, enabling clinicians to more comprehensively understand patient cardiovascular health.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-08-12
DOI
https://doi.org/10.1109/jsen.2025.3596522
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elucidating the Reactivity of Reflectance-Based Core-Body Photoplethysmogram to Posture and Respiratory Changes

Farhan Rahman, Michael Chan, Onur Selim Kılıç, Afra Nawar et al.
1 citations
IEEE Sensors Journal
Non-Invasive Vital Sign Monitoring
0.67
article

Elucidating the Reactivity of Reflectance-Based Core-Body Photoplethysmogram to Posture and Respiratory Changes

Farhan Rahman, Michael Chan, Onur Selim Kılıç, Afra Nawar, Amit Jasvant Shah, Omer T. Inan, John A. Berkebile, Chuoqi Chen
article en
1 citations

Abstract

At-home cardiovascular monitoring has become widespread with the commercialization of the photoplethysmogram (PPG) in wearable devices. A tremendous opportunity for comprehensive monitoring of chronotropic, inotropic, and vascular characteristics of the cardiovascular system can be unlocked if PPG data are combined with signals of other modalities at the core body. However, little is known about the quality of core-body PPG or its reactivity to environmental conditions. To elucidate core-body PPG signals, we compared the reactivity and quality of sternum and back PPG signals to finger-based PPG in 24 healthy participants during a protocol with posture and breathing changes. We found that signal quality of core-body PPG was affected by body location, wavelength, LED/photodiode configuration, posture, and breathing pattern. Notably, reflectance-mode red-wavelength core-body quality was less than that of transmittance-mode finger red-wavelength PPG (p<0.05). However, green-wavelength core-body PPG quality was comparable (p>0.05, sternum) or significantly greater (p<0.001, back). We also found that PPG amplitude reactivity for core-body signals was in accordance with that of the finger (p>0.05 or p<0.05, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>=</mml:mo> <mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo></mml:mrow> </mml:math> ) for posture changes but opposite (p<0.05, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>≠</mml:mo> <mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo></mml:mrow> </mml:math> ) or significantly blunted (p<0.05, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>=</mml:mo> <mml:mi>sign</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo>,</mml:mo> <mml:mi>abs</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>core</mml:mi></mml:msub> <mml:mo>)</mml:mo> <mml:mo><</mml:mo> <mml:mi>abs</mml:mi> <mml:mo>(</mml:mo> <mml:msub><mml:mi>μ</mml:mi> <mml:mi>periphery</mml:mi></mml:msub> <mml:mo>)</mml:mo></mml:mrow> </mml:math> ) during deep and resistive breathing. We, thus, demonstrate the importance of studying the reactivity of vasculature at different sensor locations as their reactivity to various provocations is heterogeneous. Our findings can be used to develop improved hardware for sensing core-body PPG and algorithms for interpreting the signals acquired, enabling clinicians to more comprehensively understand patient cardiovascular health.

IEEE Sensors JournalVol. 25(18)
Georgia Institute of Technology (US), Emory University (US), The Wallace H. Coulter Department of Biomedical Engineering (US), Rollins College (US)
National Institutes of Health, Office of Naval Research
Zero hunger
Openalex Percentile: Top 28%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.