This paper introduces a linkage-based rehabilitation device designed for low-speed gait therapy for individuals with neurological gait deficits. Unlike existing devices that operate above 0.5m/s, our system enables training at speeds between 0.1–0.4m/s, aligning with optimal rehabilitation thresholds. The device features a passive single DOF, six-link Stephenson-III mechanism mounted on a commercial treadmill. The system is designed to accurately follow an ankle-to-hip meta-trajectory, which has been extracted from 400 gait cycles of healthy individuals and adjusted for a leg length of 800mm. To ensure adjustability to users with varying physiologies, the design allows for scaling and parameter tuning based on individual anthropometrics. The final optimized mechanism was synthesized using the shadow robot algorithm, exploring 5000 initial configurations. The resulting design supports different gait trajectories through profile blending, enabling motion customization across a wide range of rehabilitation stages. A unique driving accessory transmits treadmill motion directly to the crank links, eliminating the need for separate actuators. A bodyweight support system reduces up to 80% of the patient’s weight and assists in balance control. The setup process has been streamlined for ease of use by inexperienced users by reducing the number of interaction points to two. This minimal constraint allows relative freedom for the remaining joints of the leg, enabling a more natural and patient-friendly walking experience. The device’s performance was validated using OpenSim simulations: hip and knee angle trajectories remained within ±1 standard deviation of experimental data, and root-mean-square errors were below 5 degrees throughout the gait cycle. These results demonstrate the device’s potential to provide safe, accurate, and adjustable gait rehabilitation for individuals with severe mobility impairments.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3597996
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rehabilitation Device for Low-Speed Gait Therapy Using a Passive Stephenson Mechanism on a Commercial Treadmill

Mohammad Reza Haghjoo, Ashkan Vali, Mahmood Bakhtiyari, Borhan Beigzadeh et al.
IEEE Access
Stroke Rehabilitation and Recovery
article

Rehabilitation Device for Low-Speed Gait Therapy Using a Passive Stephenson Mechanism on a Commercial Treadmill

Mohammad Reza Haghjoo, Ashkan Vali, Mahmood Bakhtiyari, Borhan Beigzadeh, Reyhaneh Chegini
article en

Abstract

This paper introduces a linkage-based rehabilitation device designed for low-speed gait therapy for individuals with neurological gait deficits. Unlike existing devices that operate above 0.5m/s, our system enables training at speeds between 0.1–0.4m/s, aligning with optimal rehabilitation thresholds. The device features a passive single DOF, six-link Stephenson-III mechanism mounted on a commercial treadmill. The system is designed to accurately follow an ankle-to-hip meta-trajectory, which has been extracted from 400 gait cycles of healthy individuals and adjusted for a leg length of 800mm. To ensure adjustability to users with varying physiologies, the design allows for scaling and parameter tuning based on individual anthropometrics. The final optimized mechanism was synthesized using the shadow robot algorithm, exploring 5000 initial configurations. The resulting design supports different gait trajectories through profile blending, enabling motion customization across a wide range of rehabilitation stages. A unique driving accessory transmits treadmill motion directly to the crank links, eliminating the need for separate actuators. A bodyweight support system reduces up to 80% of the patient’s weight and assists in balance control. The setup process has been streamlined for ease of use by inexperienced users by reducing the number of interaction points to two. This minimal constraint allows relative freedom for the remaining joints of the leg, enabling a more natural and patient-friendly walking experience. The device’s performance was validated using OpenSim simulations: hip and knee angle trajectories remained within ±1 standard deviation of experimental data, and root-mean-square errors were below 5 degrees throughout the gait cycle. These results demonstrate the device’s potential to provide safe, accurate, and adjustable gait rehabilitation for individuals with severe mobility impairments.

IEEE AccessVol. 13
Shahid Beheshti University (IR), Iran University of Science and Technology (IR)
Openalex Percentile: Top 74%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.