Indoor concentrations of radon in Cairo subway

Abstract The current study was going to detect radon concentrations in one of Cairo’s subways. The radon gas was detected in certain common positions chosen for thirteen stations. Plastic cans were prepared to hold the CR-39 samples and to be positioned at their destination in the stations. The cans were installed through two periods of one month and two months. Afterwards, the track density of radon gas was calculated for all the collected samples and then the concentration of radon was estimated in the stations. It was found that the average value of Rn concentration in the thirteen stations exceeds the average normal Rn concentration indoors. The measured values are less than the recommended maximum value of 300 Bq m −3 for radiation protection of residents according to ICRP Publ. 126. The indoor average radon concentrations were found less than the action level of 300 Bq m −3 , 100 Bq m −3 , and 148 Bq m −3 as recommended by ICRP, and WHO, respectively.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-08-01
DOI
https://doi.org/10.1088/1742-6596/3075/1/012001
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor concentrations of radon in Cairo subway

Mohamed A.E. Abdel‐Rahman, Atef El‐Taher, Nabil El‐Faramawy, Omar Abo-Bakr Omar et al.
Journal of Physics Conference Series
Radioactivity and Radon Measurements
article

Indoor concentrations of radon in Cairo subway

Mohamed A.E. Abdel‐Rahman, Atef El‐Taher, Nabil El‐Faramawy, Omar Abo-Bakr Omar, Shrouk Rawash, Mohamed El‐Kinawy
article en

Abstract

Abstract The current study was going to detect radon concentrations in one of Cairo’s subways. The radon gas was detected in certain common positions chosen for thirteen stations. Plastic cans were prepared to hold the CR-39 samples and to be positioned at their destination in the stations. The cans were installed through two periods of one month and two months. Afterwards, the track density of radon gas was calculated for all the collected samples and then the concentration of radon was estimated in the stations. It was found that the average value of Rn concentration in the thirteen stations exceeds the average normal Rn concentration indoors. The measured values are less than the recommended maximum value of 300 Bq m −3 for radiation protection of residents according to ICRP Publ. 126. The indoor average radon concentrations were found less than the action level of 300 Bq m −3 , 100 Bq m −3 , and 148 Bq m −3 as recommended by ICRP, and WHO, respectively.

Journal of Physics Conference SeriesVol. 3075(1)
Ain Shams University (EG), Al-Azhar University (EG), Military Technical College (EG)
Openalex Percentile: Top 71%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.