CPT-Based Analysis on Vertical and Horizontal Capacity of Steel Sheet Piles Installed by the Press-in with Auger

This study proposes a design method for estimating the vertical and horizontal capacity of steel sheet piles and sheet pile walls installed by the Press-in with Auger (PA) technique using Cone Penetration Test (CPT) results. The research builds upon the work of Ishihara et al. (2024) and investigates the effect of augering on the surrounding ground. Field tests were conducted in two soil types: soft cohesive soil and hard cohesionless soil. The results indicate that the vertical capacity of PA piles can be designed using modified versions of the LCPC method and Eurocode 7, with reduction factors applied to account for installation effects. Horizontal capacity can be estimated using Hetenyi's (1946) equations and Bouafia's (2014) subgrade reaction formulations, with appropriate reduction factors. The study also found that ground disturbance due to augering is limited to within 1m of the installation location. The proposed CPT-based design methods offer a practical approach for estimating PA pile and wall capacities using virgin ground CPT profiles.

Authors

Publication Details

Published
2025-05-01
DOI
https://doi.org/10.37308/dfieffc251360544
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CPT-Based Analysis on Vertical and Horizontal Capacity of Steel Sheet Piles Installed by the Press-in with Auger

Hamidou Hamadoum Tamboura
Structural Load-Bearing Analysis
article

CPT-Based Analysis on Vertical and Horizontal Capacity of Steel Sheet Piles Installed by the Press-in with Auger

Hamidou Hamadoum Tamboura
article en

Abstract

This study proposes a design method for estimating the vertical and horizontal capacity of steel sheet piles and sheet pile walls installed by the Press-in with Auger (PA) technique using Cone Penetration Test (CPT) results. The research builds upon the work of Ishihara et al. (2024) and investigates the effect of augering on the surrounding ground. Field tests were conducted in two soil types: soft cohesive soil and hard cohesionless soil. The results indicate that the vertical capacity of PA piles can be designed using modified versions of the LCPC method and Eurocode 7, with reduction factors applied to account for installation effects. Horizontal capacity can be estimated using Hetenyi's (1946) equations and Bouafia's (2014) subgrade reaction formulations, with appropriate reduction factors. The study also found that ground disturbance due to augering is limited to within 1m of the installation location. The proposed CPT-based design methods offer a practical approach for estimating PA pile and wall capacities using virgin ground CPT profiles.

Openalex Percentile: Top 79%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CPT-Based Analysis on Vertical and Horizontal Capacity of Steel Sheet Piles Installed by the Press-in with Auger — Hamidou Hamadoum Tamboura · (2025) | TGRS Research Map | TGRS