Analysis and modeling of a pneumatic artificial muscle system

Hysteresis is a common challenge in achieving precise position control of pneumatic artificial muscles (PAMs). Accurate modeling of this phenomenon is essential for the development of efficient PAM control systems. This study evaluates four mathematical models for modeling PAM dynamics: Nonlinear AutoRegressive with eXogenous inputs (NARX), BoxJenkins (BJ), Prandtl-Ishlinskii (PI), and second-order underdamped system and one zero (P2UZ). To assess the effectiveness of these models, experiments were conducted with reference input signals of varying amplitudes. The accuracy and goodness of fit of these models were evaluated based on root mean square error (RMSE) and coefficient of determination. Results show that the P2UZ model achieved the highest fitness (97.15%) and the lowest RMSE (1.80 mm), followed closely by the NARX model with 96.83% fitness and an RMSE of 1.90 mm. The PI and BJ models demonstrated lower performance, with the BJ model showing the lowest fitness (90.79%) and the highest RMSE (3.25 mm). These findings provide valuable insights for improving PAM control and PAM-based automation systems by highlighting the strengths and limitations of each model.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electrical Engineering and Computer Science
Published
2025-08-01
DOI
https://doi.org/10.11591/ijeecs.v39.i2.pp874-884
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and modeling of a pneumatic artificial muscle system

Nhut-Thanh Tran, Chi-Ngon Nguyen, Vinh-Phuc Tran, Chanh-Nghiem Nguyen
Indonesian Journal of Electrical Engineering and Computer Science
Prosthetics and Rehabilitation Robotics
article

Analysis and modeling of a pneumatic artificial muscle system

Nhut-Thanh Tran, Chi-Ngon Nguyen, Vinh-Phuc Tran, Chanh-Nghiem Nguyen
article en

Abstract

Hysteresis is a common challenge in achieving precise position control of pneumatic artificial muscles (PAMs). Accurate modeling of this phenomenon is essential for the development of efficient PAM control systems. This study evaluates four mathematical models for modeling PAM dynamics: Nonlinear AutoRegressive with eXogenous inputs (NARX), BoxJenkins (BJ), Prandtl-Ishlinskii (PI), and second-order underdamped system and one zero (P2UZ). To assess the effectiveness of these models, experiments were conducted with reference input signals of varying amplitudes. The accuracy and goodness of fit of these models were evaluated based on root mean square error (RMSE) and coefficient of determination. Results show that the P2UZ model achieved the highest fitness (97.15%) and the lowest RMSE (1.80 mm), followed closely by the NARX model with 96.83% fitness and an RMSE of 1.90 mm. The PI and BJ models demonstrated lower performance, with the BJ model showing the lowest fitness (90.79%) and the highest RMSE (3.25 mm). These findings provide valuable insights for improving PAM control and PAM-based automation systems by highlighting the strengths and limitations of each model.

Indonesian Journal of Electrical Engineering and Computer ScienceVol. 39(2)
Can Tho University (VN)
Openalex Percentile: Top 81%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.