Heart rate estimation for U-Net and LSTM models combining multiple attention mechanisms

Accurate heart rate (HR) monitoring is pivotal in modern medical technology, particularly for disease prevention and health management. This study proposes a novel HR estimation framework that leverages advanced deep learning techniques to accurately extract HR information from noisy photoplethysmography (PPG) signals. The proposed model, termed DRL-Unet, integrates a Denoising Autoencoder (DAE), U-Net architecture, and Long Short-Term Memory (LSTM) networks. To further enhance robustness and precision, the model incorporates a Multi-Head Attention mechanism and Residual Network (ResNet) modules. Comparative experiments demonstrate that DRL-Unet outperforms conventional deep learning models, achieving a Mean Absolute Error (MAE) of 1.69 bpm, Mean Squared Error (MSE) of 3.05 bpm², Root Mean Squared Error (RMSE) of 1.71 bpm, Mean Absolute Percentage Error (MAPE) of 1.15%, and Bias of 0.05 bpm. The model's effectiveness is validated on a public dataset from the IEEE Signal Processing Cup, confirming its superior performance under complex noise conditions. These findings highlight the potential of DRL-Unet to significantly improve the accuracy and reliability of HR estimation, thereby offering valuable advancements for early cardiovascular disease diagnosis and continuous health monitoring.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2025-08-10
DOI
https://doi.org/10.1016/j.medengphy.2025.104406
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heart rate estimation for U-Net and LSTM models combining multiple attention mechanisms

Jun Cai, A. Li
Medical Engineering & Physics
Non-Invasive Vital Sign Monitoring
article

Heart rate estimation for U-Net and LSTM models combining multiple attention mechanisms

Jun Cai, A. Li
article en

Abstract

Accurate heart rate (HR) monitoring is pivotal in modern medical technology, particularly for disease prevention and health management. This study proposes a novel HR estimation framework that leverages advanced deep learning techniques to accurately extract HR information from noisy photoplethysmography (PPG) signals. The proposed model, termed DRL-Unet, integrates a Denoising Autoencoder (DAE), U-Net architecture, and Long Short-Term Memory (LSTM) networks. To further enhance robustness and precision, the model incorporates a Multi-Head Attention mechanism and Residual Network (ResNet) modules. Comparative experiments demonstrate that DRL-Unet outperforms conventional deep learning models, achieving a Mean Absolute Error (MAE) of 1.69 bpm, Mean Squared Error (MSE) of 3.05 bpm², Root Mean Squared Error (RMSE) of 1.71 bpm, Mean Absolute Percentage Error (MAPE) of 1.15%, and Bias of 0.05 bpm. The model's effectiveness is validated on a public dataset from the IEEE Signal Processing Cup, confirming its superior performance under complex noise conditions. These findings highlight the potential of DRL-Unet to significantly improve the accuracy and reliability of HR estimation, thereby offering valuable advancements for early cardiovascular disease diagnosis and continuous health monitoring.

Medical Engineering & PhysicsVol. 145(1)
Anhui University (CN), Anhui University of Science and Technology (CN)
Openalex Percentile: Top 81%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.